Tofino Xenon Security Appliance Tofino SA
Release 04 05/2015
1.6.2
100 Mbit/s F/O port
The 100 Mbit/s F/O port offers you the ability to connect network components
according to the IEEE 802.3 100BASE-FX standard.
This port supports:
Full or half duplex mode
Default setting: Full duplex
1.7
Display elements
After the supply voltage is set up, the software starts and initializes itself.
Afterwards, the device performs a self-test.
1.7.1
Device state
These LEDs provide information about conditions which affect the operation
of the whole device.
LED
Display
Color Activity
Meaning
POWER Supply voltage
—
None
Supply voltage is too low
Yellow Lights up
Supply voltage 1
or
2 is on
Green Lights up
Supply voltages 1
and
2 are on
NET 1
and
NET 2
Link status
—
None
Device detects an invalid or missing link
Green Lights up
Device detects a valid link
Flashes 3 times
a period
Port is switched off
Yellow Flashing
Device is transmitting and/or receiving
data
FAULT System and USB
save/load errors
Red
None
The signal contact is closed - it is
not
reporting any detected errors.
Very short
flashing in
cycles of 0.5 s
A detected USB load or save error
occurred.
See table 8 on page 28.
MODE
Network mode
Green None
The device is in Unconfigured mode.
Lights up
The device is in operational mode.
Long flashing
The device is in test mode.
SAVE/
LOAD
Preparation
Saving process
Green Lights up (5 s) The saving of the device diagnostic or log
files to the USB storage device is about to
begin.
Preparation
Loading process
Yellow Lights up (5 s) The load of the configuration files from the
USB storage device is about to begin.
POWER