Lanner NCA-4010 Series Скачать руководство пользователя страница 1

                                         

Network Computing Platforms

 

 

 

 

 

 

 

 

 

 

 

  NCA-4010 

 

User Manual 

 

 

Rev 1.5                                            Sep 11

th

, 2018 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание NCA-4010 Series

Страница 1: ...Network Computing Platforms NCA 4010 User Manual Rev 1 5 Sep 11th 2018...

Страница 2: ...changes in content from time to time without obligation on the part of Lanner Electronics Inc to provide notification of such revision or change The information in this document is furnished for info...

Страница 3: ...enclosure products FCC Class A Certification This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are desig...

Страница 4: ...ower is disconnected from a circuit always check the circuit LITHIUM BATTERY CAUTION Risk of explosion could occur if battery is replaced by an incorrect type Please dispose of used batteries accordin...

Страница 5: ...achieved due to uneven mechanical loading 4 Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits m...

Страница 6: ...e site propose une circulation d air adequate Verifiez que le couvercle du chassis est bien fixe La conception du chassis permet a l air de refroidissement de bien circuler Un chassis ouvert laisse l...

Страница 7: ...n CC Desserrez la vis du terminal de mise a la terre Branchez le cable de mise a la terre a la terre L appareil de protection pour la source d alimentation CC doit fournir 30 A de courant Cet appareil...

Страница 8: ...tup 37 About the CPU Heatsink and Heat radiation Bracket 38 Installing the System Memory 39 Installing Disk Drives 40 Installing a mSATA Module 43 Installing an IPMI Card Project based 44 Replacing Co...

Страница 9: ...90 Security 91 Boot 92 Save Exit 95 Appendix A Programming Watchdog Timer 101 Appendix B Setting up Console Redirection 102 Appendix C Programming Generation 3 LAN Bypass 103 Appendix D Programming t...

Страница 10: ...irs of LAN bypass vary depending on models 1 x NIC module slots support 40G 10G 1G Fiber Copper Bypass 2 x DDR4 REG ECC UDIMM memory sockets at 2400 MHz up to 16GB each 1 x 3 5 or 2 x 2 5 SATA HDD SSD...

Страница 11: ...S HDD Keypad 4x Keypads Expansion 2 x PCIe Gen3x4 expansions for upper layer expansion Model A C only 1 x PCIe Gen3x8 expansion at rear optional TPM Optional Thermal 1 x passive heat sink Physical Cha...

Страница 12: ...4010D 1U x86 Rackmount Network Appliance based on Intel Xeon D 1548 Processor codename Broadwell DE SoC 8 GbE RJ45 with 2 SFP 10GbE ports 1 NIC Module Slot and 3 pairs of LAN bypass Package Contents...

Страница 13: ...Network Computing Platforms Chapter 2 System Overview Mechanical Drawing Unit mm...

Страница 14: ...etwork Computing Platforms Block Diagram Note TPM is optional The diagram is based on 8 x RJ 45 GbE design The number of LAN ports is 16 for model A The 2 x 10G SFP ports are only available in model A...

Страница 15: ...ies HDD status about storage devices such as HDD or SSD F2 LCM LCM with 4 x keypads F3 Console 1 x RJ 45 console port F4 USB 2 x USB 2 0 Type A ports in double stacked form F5 LAN 8 or 16 x RJ 45 GbE...

Страница 16: ...ing Platforms Rear I Os R1 PCIe Expansion 1 x PCIe expansion slot optional R2 Fans 2 x cooling fans R3 Power switch 1 x power on off switch R4 power jack 1 x power jack for connection with power adapt...

Страница 17: ...mputing Platforms Chapter 3 Board Layout Jumpers and Connectors on the Motherboard ATX1 SATAPWR1 2 JLCM1 JDDR1 2 J4 JPCIESLOT1 COMB1 USB1 LAN J1 2 JSATA1 2 FAN1 2 JMSATA1 J9 10 11 JBIOS1 JOPMA1 ATX2 C...

Страница 18: ...Network Computing Platforms Jumpers and Connectors on the Motherboard cont d JTPM1 JSPIROM1 JCMOS1...

Страница 19: ...Connector Pin out ATX1 24 pin ATX power connector PIN DESCRIPTION PIN DESCRIPTION 1 3 3V 2 3 3V 3 3 3V 4 12V 5 GND 6 GND 7 5V 8 PSON 9 GND 10 GND 11 5V 12 GND 13 GND 14 GND 15 ATXPWGD 16 5V 17 5VSB 1...

Страница 20: ...tforms ATX2 4 pin ATX power connector COMA1 internal serial COM pin header PIN DESCRIPTION PIN DESCRIPTION 1 NDCD2 2 NDSR2 3 NRXD2 4 NRTS2 5 NTXD2 6 NCTS2 7 NDTR2 8 NRI2 9 GND 10 NC PIN DESCRIPTION 1...

Страница 21: ...puting Platforms CONN2 2 pin power connector for the power button on the panel PIN DESCRIPTION 1 POWER ON 2 GND FAN1 2 2 x 5 pin cooling fan connectors PIN DESCRIPTION 1 CPUFANOUTPWM 2 NC 3 CPUFANIN 4...

Страница 22: ...G401 J1 PIN DESCRIPTION PIN DESCRIPTION A1 P3V3 B1 P12V A2 P3V3 B2 P12V A3 P3V3 B3 PCH_SLOT3_A8 A4 GND B4 PCIESLOT3_I350A_RST A5 P3V3 B5 PHY_WAKE A6 GND B6 GND A7 SLT3A_SCLK2 B7 CLK100_PCIE_SOLT3_1P A...

Страница 23: ...0 PCIE_CTX_C_SLOT3RX_P2 B20 PCIE_SLOT3TX_C_CRX_P2 A21 PCIE_CTX_C_SLOT3RX_N2 B21 PCIE_SLOT3TX_C_CRX_N2 A22 GND B22 GND A23 PCIE_CTX_C_SLOT3RX_P3 B23 PCIE_SLOT3TX_C_CRX_P3 A24 PCIE_CTX_C_SLOT3RX_N3 B24...

Страница 24: ...IE_SLOT3TX_C_CRX_P5 A18 PCIE_CTX_C_SLOT3RX_N5 B18 PCIE_SLOT3TX_C_CRX_N5 A19 GND B19 GND A20 PCIE_CTX_C_SLOT3RX_P6 B20 PCIE_SLOT3TX_C_CRX_P6 A21 PCIE_CTX_C_SLOT3RX_N6 B21 PCIE_SLOT3TX_C_CRX_N6 A22 GND...

Страница 25: ...PASS J7 Fresh main board BYPASS PIN DESCRIPTION PIN DESCRIPTION 1 NC 2 NC 3 IO_NXP_RXD 4 IO_NXP_RTS_N 5 IO_NXP_TXD 6 IO_NXP_CTS_N 7 NC 8 NC 9 GND 10 GND PIN DESCRIPTION PIN DESCRIPTION 1 NC 2 NC 3 NXP...

Страница 26: ...rk Computing Platforms J8 Main board ARM Programming Selection 0 2 3 Enable 1 1 2 Disable default J9 J10 PHY I2C Source Selection 2 3 From Tool 1 2 From CPU default PIN DESCRIPTION 1 P3V3 2 CPLD_LED3...

Страница 27: ...PIN DESCRIPTION 1 PHY_I2C_SDA 2 PHY_I2C_SDA_JUMP 3 PHY_I2C_SDA_TOOL J10 PIN DESCRIPTION 1 PHY_I2C_SCL 2 PHY_I2C_SCL_JUMP 3 PHY_I2C_SCL_TOOL J11 PHY I2C debug pin header PIN DESCRIPTION 1 PHY_I2C_SDA_...

Страница 28: ...sh BIOS JCMOS1 1 2 NORMAL 2 3 CLEAR CMOS PIN DESCRIPTION PIN DESCRIPTION 1 CLK_33M_PORT80 2 LPC_LAD1_R 3 80PORT_RST 4 LPC_LAD0_R 5 LPC_FRAME _P80 6 P3V3 7 LPC_LAD3_P80 8 NC 9 LPC_LAD2_P80 10 GND PIN D...

Страница 29: ...Platforms PIN DESCRIPTION 1 VCC_RTC 2 PCH_RTCRST 3 GND JCPLD1 Fresh CPLD Complex Programmable Logic Device JLCM1 LCM module connector PIN DESCRIPTION 1 P3V3_SB 2 DUAL_SPI_TDO 3 J_CPLD_TDI 4 CPLD_TMS...

Страница 30: ...N DESCRIPTION PIN DESCRIPTION 1 P5V 2 GND 3 P_SLIN_N 4 VEE 5 P_AFD_N 6 P_INIT_N 7 LPD1 8 LPD0 9 LPD3 10 LPD2 11 LPD5 12 LPD4 13 LPD7 14 LPD6 15 LCD 16 P5V 17 KPA1 18 KPA2 19 KPA3 20 KPA4 21 LCM_RST 22...

Страница 31: ...rk Computing Platforms JMSATA1 mSATA module PIN DESCRIPTION PIN DESCRIPTION 1 NC 2 P3V3 3 NC 4 GND 5 NC 6 NC 7 NC 8 NC 9 GND 10 NC 11 NC 12 NC 13 NC 14 NC 15 GND 16 NC 17 NC 18 GND 19 NC 20 NC 21 GND...

Страница 32: ...3 25 SATA_DTX_CRX_N1 26 GND 27 GND 28 NC 29 GND 30 NC 31 SATA_CTX_C_DRX_N1 32 NC 33 SATA_CTX_C_DRX_P1 34 GND 35 GND 36 NC 37 GND 38 NC 39 P3V3 40 GND 41 P3V3 42 NC 43 GND 44 NC 45 NC 46 NC 47 NC 48 NC...

Страница 33: ...mputing Platforms JRESET1 Select front panel reset option 1 2 Hardware Reset 2 3 Software Reset Default JSATA1 JSATA2 SATA connectors for storage devices PIN DESCRIPTION 1 BTN_SYS_RESET 2 FP_RESET 3 S...

Страница 34: ...SCRIPTION 1 GND 2 SATA_CTX_C_DRX_P2 3 SATA_CTX_C_DRX_N2 4 GND 5 SATA_DTX_CRX_N2 6 SATA_DTX_CRX_P2 7 GND JSATA2 PIN DESCRIPTION 1 GND 2 SATA_CTX_C_DRX_P3 3 SATA_CTX_C_DRX_N3 4 GND 5 SATA_DTX_CRX_N3 6 S...

Страница 35: ...SPI1_CS0 _DUAL 4 P3V3_SB 5 SPI_MISO_DUAL 6 SPI_HOLD0_L 7 NC 8 SPI_CLK_DUAL 9 GND 10 SPI_MOSI_DUAL JTPM1 TPM module pin header optional PIN DESCRIPTION PIN DESCRIPTION 1 LPC_SERIRQ 2 LPC_FRAME 3 LPC_LA...

Страница 36: ...internal connector PIN DESCRIPTION PIN DESCRIPTION 1 DAC_RO 2 GND 3 DAC_GO 4 GND 5 DAC_BO 6 GND 7 HSYNC_O 8 NC 9 VSYNC_O 10 GND 11 DDC_DATA 12 DDC_CLK SATAPWR1 SATAPWR2 SATA 4 pin POWER connectors PIN...

Страница 37: ...ing procedures first WARNING To reduce the risk of personal injury electric shock or damage to the equipment please remove all power sources Please wear ESD protected gloves before conducting the foll...

Страница 38: ...soldered onboard the heatsink and the heat radiation brackets are pre installed before shipment In normal circumstances no installation nor replacement is required If there is any issue related to CPU...

Страница 39: ...ocket Please follow the steps below to install the DIMM memory modules 1 Power off the system and locate the DDR DIMM slot 2 Pull open the DIMM slot latches 3 Align the DIMM module and make sure the n...

Страница 40: ...HDDs or SSDs as data storage Please follow the steps below for installation Note the following steps are based on 2 x 2 5 SATA disk drives installation 1 Locate the disk drive tray at the corner of th...

Страница 41: ...disk drive as shown in the image below Apply 2 screws for each side of the disk drive 5 Place the tray with HDD SSD installed back to its original spot inside the system Remember to aim the two latch...

Страница 42: ...uting Platforms 6 Establish SATA cable connection between the disk drive and the motherboard Please apply 15 7 SATA cable to the drive while using SATA 7 pin connector and SATA 4 pin connector for the...

Страница 43: ...A Module The motherboard provides one mSATA slot Follow the procedures below for installing a mSATA card 1 Locate the mSATA socket 2 Insert a mSATA module as shown in the image below card 3 Press the...

Страница 44: ...an IPMI Card Project based The motherboard provides one OPMA socket which is used to install an IPMI card Please follow the steps below for instructions 1 Locate the OPMA socket 2 Insert an IPMI card...

Страница 45: ...orms 3 Apply a screw to secure the IPMI card Notes The remake about the IPMI support requires changes in BOM and it is based on custom projects For requirements about IPMI support please consult with...

Страница 46: ...g fans To replace a worn down fan please follow the steps below 1 Remove the screws circled below 2 Apply some force and pull the fan out of its original place as shown in the image below 3 To install...

Страница 47: ...rmation about compatible modules please refer to the Ordering Information and Optional Accessories sections or contact Lanner for more details 1 Remove the two captive screws on the bezel of the modul...

Страница 48: ...Network Computing Platforms 3 Slide your Ethernet NIC module into the space until it is firmly attached 4 Secure the module with two captive screws on the bezel...

Страница 49: ...ils 1 x pack of screws 2 Turn a slide rail upside down and release the inner bracket 4 Slide the inner bracket all the way up to end of the slide rail assembly You may hear a click sound 5 Push the wh...

Страница 50: ...side of the chassis Installing Slide Rails 1 In the previous section you have already detached the inner brackets and attached them onto the chassis of your purchased model By now you shall install th...

Страница 51: ...orms 2 For the rear rack installation also aim at 3 available holes and click the slide rail assembly onto the rear rack 3 Repeat Step 1 and 2 for another slide rail assembly in order to install in on...

Страница 52: ...Network Computing Platforms...

Страница 53: ...ongly recommended to carry out this procedure with two or three persons 1 Hold the applicable model with its front facing you lift the chassis and gently insert the model by aligning with the slide ra...

Страница 54: ...aneously push the release tabs on both sides in the arrow of direction below while pushing the appliance into the end of the rack Caution the appliance will be locked during the half way of sliding in...

Страница 55: ...ng Platforms 3 Slide the appliance all the way into the assembly until it reaches its end 4 To slide the appliance out gently pull it outwards Then press the slide rail locks on both side and slide th...

Страница 56: ...lect a setup screen for instance Main Advanced Chipset Boot Security and Save Exit select an item option on a setup screen Enter select an item option or enter a sub menu ESC exit the current screen t...

Страница 57: ...Information BIOS Vendor displays BIOS vendor information Core Version displays the BIOS core version Compliancy displays the BIOS compliancy Project Version displays BIOS project version Build Date an...

Страница 58: ...ect Advanced setup screen Under this screen you may use to select an item you wish to configure PXE Function This option allows users to set PXE Preboot Execution Environment functions Users may enabl...

Страница 59: ...ease be noted that TPM module shall have been installed first in order to make any configuration Security Device Support this enables or disables BIOS support for security device Please be noted that...

Страница 60: ...ss configuration sub menu for super IO chip NCT6776 parameters You may access settings for Serial Port 1 or 2 or the Parallel port NCT6776 Super IO Configuration Serial Port 1 Configuration The super...

Страница 61: ...disable the Serial Port 1 COMA Device setting is fixed as default NCT6776 Super IO Configuration Serial Port 2 Configuration Once Serial Port 2 is accessed you may press Enter to enable or disable the...

Страница 62: ...Network Computing Platforms Parallel Port Configuration This option allows you to set parameters for parallel port LPT LPTE...

Страница 63: ...ting Platforms Once Parallel Port is accessed you may press Enter to enable or disable the Parallel Port Device setting is fixed as default NCT76776 HW Monitor This option allows you to view hardware...

Страница 64: ...Network Computing Platforms Serial Port Console Redirection This option allows you to configure parameters about serial port console redirection Press Enter to access the submenu...

Страница 65: ...Network Computing Platforms Console Redirection select Enabled or Disable for COM port console redirection The default is Enabled...

Страница 66: ...ub menu COM Console Redirection Settings Terminal Type the emulation configuration Select VT100 VT100 VT UTF8 or ANSI VT100 ASCII character set VT100 extends VT100 to support color function keys VT UT...

Страница 67: ...0 19200 38400 57600 or 115200 for bits per second The Bps will determine serial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds Data Bi...

Страница 68: ...bit can be sent with the data bits to detect some transmission errors Select None Even Odd Mark or Space Stop Bits stop bits indicate the end of a serial data packet The standard is 1 stop bit Communi...

Страница 69: ...erflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow You may select None or Hardware RTS CTS depending on the circumstances VT UTF8 Combo Key Supp...

Страница 70: ...etwork Computing Platforms Recorder Mode on this mode when Enabled only text will be sent This is to capture terminal data Resolution 100 x 31 select Enable or Disable for extended terminal resolution...

Страница 71: ...uting Platforms Legacy OS Redirection Resolution select 80x24 or 80x25 The default for this case is 80x24 Putty KeyPad select Function Key and Key Pad on Putty You may select VT100 LINUX XTERMR6 SCO E...

Страница 72: ...y if BootLoader is selected than Legacy console redirection is disabled before booting to Legacy OS Default value is Always Enable which means Legacy OS console redirection is always enabled after BIO...

Страница 73: ...is function enables or disables legacy USB support Auto option disables legacy support if no USB devices are connected Disable option will keep USB devices available only for EFI applications EHCI Han...

Страница 74: ...n allows you to enable or disable USB mass storage driver The default is Enabled Port 60 64 Emulation this option enables I O port 60h 64h emulation support This should be enabled for the complete USB...

Страница 75: ...Platforms USB transfer time out set USB time out value 1 5 10 or 20 seconds for Control Bulk and Interrupt transfers Device reset time out set USB mass storage device Start Unit command time out 10 20...

Страница 76: ...k Computing Platforms Device power up delay set the maximum time the device will take before it properly reports itself to the Host Controller Auto uses default value For example it is 100ms as a root...

Страница 77: ...s to change processor settings Press Enter to access its sub menu Under Process Configuration information about the CPU including socket ID frequency and cache information will be displayed Execute Di...

Страница 78: ...S NI enables or disables AES NI Advanced Encryption Standard New Instruction support Memory Configuration Memory Configuration displays and provides options to change the memory settings You may press...

Страница 79: ...ork Computing Platforms Memory Topology this option displays memory topology with DIMM population information Each socket has 2 nodes iMC s numbered from 0 to 7 Each node supports up to 2 channels 0 a...

Страница 80: ...uting Platforms PCH Configuration This function allows users to view and configure PCH settings Press Enter to access the sub menu PCH SATA Configuration Press Enter to access items for SATA devices a...

Страница 81: ...Computing Platforms SATA Controller enables or disables SATA controller Configure SATA as this item identifies whether the SATA port is connected to a SSD and HDD Select IDE AHCI or RAID The default...

Страница 82: ...omputing Platforms mSATA displays status of mSATA storage device Software Preserve displays information of Software Preserve mSATA enable or disable mSATA socket Hot Plug designates this port as hot p...

Страница 83: ...s eSATA configures the port as External SATA eSATA Spin Up Device if enabled for any of ports Staggered Spin Up will be performed and only the drives which have this option enabled will spin up at boo...

Страница 84: ...Network Computing Platforms SATA Device Type identifies the SATA port is connected to SSD Solid State Drive or HDD Hard Disk Drive SATA1 enable or disable the SATA port...

Страница 85: ...work Computing Platforms SATA1 DevSlp enable or disable the SATA port Device Sleep Board rework for LP is needed before enabling this power saving function Hot Plug designates this port as hot pluggab...

Страница 86: ...s eSATA configures the port as External SATA eSATA Spin Up Device if enabled for any of ports Staggered Spin Up will be performed and only the drives which have this option enabled will spin up at boo...

Страница 87: ...Network Computing Platforms SATA Device Type identifies the SATA port is connected to SSD Solid State Drive or HDD Hard Disk Drive SATA2 enable or disable the SATA port...

Страница 88: ...Network Computing Platforms Hot Plug designates this port as hot pluggable Configure as eSATA configures the port as External SATA eSATA...

Страница 89: ...ny of ports Staggered Spin Up will be performed and only the drives which have this option enabled will spin up at boot Otherwise all drives spin up at boot SATA Device Type identifies the SATA port i...

Страница 90: ...Network Computing Platforms PCH State after G3 Select S0 S5 for ACPI state after a G3 The choices are S0 S5 or Last State...

Страница 91: ...want to configure Administrator Password set administrator password Once set then this only limits access to Setup and is only asked for when entering Setup User Password set user password Once set t...

Страница 92: ...creen Under this screen you may use to select an item you want to configure Boot Configuration Setup Prompt Timeout number of seconds to wait for setup activation key 65535 0xFFFF means indefinite wai...

Страница 93: ...uiet Boot this option allows you to enable or disable Quiet Boot The default is Disabled based on Intel s server environment setting Boot Option Priorities Boot Option 1 2 set devices as boot option 1...

Страница 94: ...Network Computing Platforms USB Device BBS Priorities set the order of the legacy devices in this group...

Страница 95: ...es Save Changes and Reset reset the system after saving the configuration changes Discard Changes and Reset reset the system without saving the configuration changes Save Options Save Changes save the...

Страница 96: ...Network Computing Platforms Save Changes and Exit exit system setup after saving the configuration changes Discard Changes and Exit exit system setup without saving the configuration changes...

Страница 97: ...Network Computing Platforms Save Changes and Reset reset the system after saving the configuration changes Discard Changes and Reset reset the system without saving the configuration changes...

Страница 98: ...Network Computing Platforms Save Changes save the configuration changes done so far Discard Changes discard all the configuration changes...

Страница 99: ...Network Computing Platforms Restore Defaults restore load factory default setting for all setup parameters Save as User Defaults save changes done so far as user default...

Страница 100: ...Network Computing Platforms Restore User Defaults restore the user default...

Страница 101: ...er is based on a counter that counts down from an initial value to zero The software selects the counter s initial value and periodically restarts it Should the counter reach zero before the software...

Страница 102: ...le port of the system and the other end to serial port of the Remote Client System 2 Configure the following settings in the BIOS Setup menu BIOS Advanced Remote Access Configuration Serial Port Mode...

Страница 103: ...s 1 Communication through SMBUS I2C 2 Independent bypass status control for each pair up to a total of 4 pairs 3 Lanner Bypass Modules can bypass systems Ethernet ports on a host system during three i...

Страница 104: ...wnload center and browse the download center and look for Lanner LAN Bypass Watchdog User Manual under the Accessories folder Fro a description of the physical LAN ports equipped with this function re...

Страница 105: ...See next section For Parallel Text based LCM Build To build program source code on Linux platform please use the following steps as a guideline 1 Extract the source file tar xzvf plcm_drv_v0XX tgz 0X...

Страница 106: ...ing off on the backlight of the LCM display Display Off turning off the LCM display Cursor Off On NOT showing showing the cursor on the LCM display Blinking off On turning off on the cursor blinking W...

Страница 107: ...ct Item 1 to set the starting line as either line 1 or line 2 Move cursor right select Item 2 to move the cursor to the right Move cursor left select Item 3 to move the cursor to the left Add a char s...

Страница 108: ...xample add to etc libvirt qemu yourvirtualmachine xml in linux KVM parallel type dev source path dev parport0 target port 0 parallel 3 Open a terminal in the Guest OS and then issue the following comm...

Страница 109: ...modprobe parport_pc modprobe ppdev 4 Check that whether the dev parport0 exists or not You may not find proper dev parport0 in the device list please reconfirm the setup of VMWare Player s setting pag...

Страница 110: ...at customer s expense 5 The following conditions are excluded from this warranty Improper or inadequate maintenance by the customer Unauthorized modification misuse or reversed engineering of the prod...

Страница 111: ...Network Computing Platforms...

Отзывы: