![Toa VX-3308WM Скачать руководство пользователя страница 78](http://html.mh-extra.com/html/toa/vx-3308wm/vx-3308wm_operating-instructions-manual_1123506078.webp)
Chapter 3
OPERATION
3-
19
4.3. Making All-zone Emergency Broadcast from the RM-200SF
Step 1.
Set the CPU switch on the front surface to OFF.
Tip:
The CPU switch is factory-preset to ON.
RM-200SF front
Notes
• The RM-200SF's DIP switch 6 (factory default:
ON) must be preset to ON to enable the CPU
OFF function (all-zone emergency broadcast).
• The event being activated from the remote
microphone will be cleared when the system is
placed in the CPU OFF state, and not restarted
when its state is released.
RM-200SF rear
Step 2.
Make the microphone announcement while holding down the Talk key.
Talk key
Step 3.
When the microphone announcement is complete, return the CPU switch to ON.
RM-200SF
FIREMAN'S
MICROPHONE
CPU
OFF
MIC SP CPU
OFF ON
DIP SWITCH
Of f
On
1
2
U N IT ID
3
4
C OM M U N IC A T IO N
5
LEV EL M ET ER
6
C PU
OFF 7
8 TER M IN A T IO N
1
ON
2
3
4
5
6
7
8
Содержание VX-3308WM
Страница 5: ...Chapter 1 NOMENCLATURE ...
Страница 6: ...Chapter 1 NOMENCLATURE 1 2 1 Front VX 3308WM VOICE EVACUATION WALL MOUNT ...
Страница 14: ...Chapter 2 INDICATOR STATUS OF REMOTE MICROPHONES ...
Страница 60: ...Chapter 3 OPERATION ...