Toa VX-3308WM Скачать руководство пользователя страница 73

Chapter 3

OPERATION

3-

14

Step 3.

When making broadcast using the RM-200SF, follow

the procedures below.

• Press the All-Zone Call key (4) to select all zones.

In this event, the Selection indicator lights.

Zone monitor indicator

Selection indicator

All-Zone Call key

Green

• Press the Talk key (5), then make voice

announcements to all zones.

In this event, the Broadcast status indicator lights

yellow, and the Microphone indicator lights green.

Talk key

5

Broadcast Status Indicator

Microphone Indicator

Yellow

Green

Also, the Zone monitor indicator of the All-Zone Call

key (4) lights yellow.

Zone monitor indicator

Selection indicator

All-Zone Call key

Tip

Yellow

Green

When a Fireman's Microphone announcement interrupts a message broadcast, the broadcast mode

that follows Fireman's Microphone announcement completion can be set to either "Continue" for

continuous EV message broadcast or "Silent" for broadcast termination. This setting can be made by

using the VX-3000 Setting Software.

Step 4.

Terminate the Emergency status.

Press the Emergency Reset key (3).

The restoration message is broadcast to the entire zone, and the

Restoration EV message status indicator of the Emergency Reset

key (3) lights while the message is broadcast.

After the message broadcast completion, the VX-3000 system

is restored from Emergency status to the General-purpose

broadcast status, and the Emergency status indicator (1) built in

the Emergency key goes off.

Emergency key

Goes off

Restoration EV message

status indicator

Green

Emergency Reset key

4

4

3

1

Содержание VX-3308WM

Страница 1: ...STRUCTIONS VOICE EVACUATION WALL MOUNT VX 3308WM Thank you for purchasing TOA s Voice Evacuation Wall Mount Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment ...

Страница 2: ...r State at the Time of Emergency Broadcast Pattern Start 2 9 1 11 Indicator State at the Time of Emergency Broadcast Pattern Stop 2 10 1 12 Indicator State at the Time of Emergency Broadcast Pattern Start Stop 2 11 1 13 Indicator State at the Time of Emergency Sequence Stop 2 12 1 14 Indicator State at the Time of Emergency Sequence Phase Shift 2 13 1 15 Indicator State at the Time of Emergency Re...

Страница 3: ...y EV Broadcast 2 38 2 18 Indicator State at the Time of Emergency Acknowledge 2 39 2 19 Indicator State at the Time of Disablement of EMG Control from CIN 2 41 2 20 Indicator State at the Time of Audio Monitor 2 42 2 21 Indicator State at the Time of Intended Control Input 2 42 2 22 Indicator State at the Time of Intended Control Output Pulse 2 43 2 23 Indicator State at the Time of Intended Contr...

Страница 4: ... Terminals 3 24 6 LAMP TEST 3 25 6 1 Remote Microphone s Operation Example 3 25 6 2 VX 3308WM s Operation 3 26 7 OTHER FUNCTIONS 3 27 7 1 Audio Monitor 3 27 7 2 Intended Control Input Operation 3 28 7 3 Intended Control Output Operation Pulse 3 28 7 4 Intended Control Output Operation Level 3 29 ...

Страница 5: ...Chapter 1 NOMENCLATURE ...

Страница 6: ...Chapter 1 NOMENCLATURE 1 2 1 Front VX 3308WM VOICE EVACUATION WALL MOUNT ...

Страница 7: ...lled 10 Amplifier signal indicators Green Show the input signal state to the power amplifier when the power amplifier module is installed The indicator corresponding to the module slot port will light if the input signal level exceeds 25 dB 2 It remains unlit when no power amplifier module is installed 2 0 dB 1 V 11 Amplifier operate indicators Green The indicator corresponding to the module slot ...

Страница 8: ...it and the buzzer sounds as long as this key is pressed 24 Battery indicator BATTERY POWER Indicates the state of battery usage Lights green when the AC power supply is interrupted and switched over to the backup batteries 25 Battery connection indicator BATTERY CONNECT Lights green when the battery is connected 26 Charging indicator CHARGING Indicates battery charging status Flashes green while c...

Страница 9: ...alfunctions Failures of Emergency buttons and signal both control and audio path between the microphone including the internal microphone element and the VX 3000 are automatically detected Front 1 Power indicator Green Lights when the power is turned on 2 Emergency key Assign the function concerning the emergency broadcast to this key using the VX 3000 Setting Software This key lights or flashes d...

Страница 10: ...ed placing the RM 200SF in reset state 12 Status indicators Red Yellow Green Light flash or go off depending on the current operation state of function keys failure state or emergency state See the Chapter 2 13 Selection indicators Green Light or go off depending on the current operation state of function keys See the Chapter 2 14 Function keys R1 R3 Positioned in top down order R1 R2 R3 Pressing ...

Страница 11: ...indicators Red Yellow Green Light flash or go off depending on the current operation state of function keys 4 Selection indicators Green Light or go off depending on the current operation state of function keys 5 Function keys 1 20 Keys are numbered from 1 to 10 from upper left to bottom and from 11 to 20 from upper right to bottom Pressing a specific function key executes the function that has be...

Страница 12: ...dicator Green Lights when the power is turned on 3 Failure indicator Yellow Red Flashes yellow if some problem within thesystem is detected This indicator will light yellow if the signal to the VX 3308WM to which the RM 300X is connected is interrupted for 5 seconds or more This indicator will light red while the all zone emergency broadcasts is being made p 3 17 or the RM 300X is in the reset pro...

Страница 13: ...me at the beginning and or end of each broadcast The Talk key mode PTT or Lock and the chime function are set using the VX 3000 Setting Software See the separate Setting Software Instructions Unit Configuration Setting 11 Function keys L1 L3 Positioned in top down order L1 L2 L3 These keys operate in the same manner as the Function keys R1 R10 9 12 Broadcast status indicator Yellow Green Lights fl...

Страница 14: ...Chapter 2 INDICATOR STATUS OF REMOTE MICROPHONES ...

Страница 15: ...e Selection key not in use or BGM broadcast in progress Flashes green A part of zones or the entire zone assigned to this Broadcast Zone Selection key is occupied by a broadcast from another device secondary Remote Microphone or general EV message or a part of zones is engaged by a broadcast from the primary Remote Microphone RM 200SF Lights yellow All the zones selected by this Broadcast Zone Sel...

Страница 16: ...Remote Microphone Broadcast Status Indicator Unlit Zone not in use microphone announcement possible Flashes green A part of zones or the entire zone selected by the primary Remote Microphone is occupied by a broadcast from another device secondary Remote Microphone chime etc or a broadcast from the primary Remote Microphone is in progress in a part of the zones selected by the primary Remote Micro...

Страница 17: ...g broadcast Lights yellow When the Base pattern assigned to the function key is being broadcast including broadcasts activated by other devices 1 4 Indicator State at the Time of General Purpose Broadcast Pattern When a general purpose broadcast pattern function has been assigned to a function key the 2 indicators to the left of the key indicate its pattern selection and broadcast status Note For ...

Страница 18: ... activated Lights green When a general BGM broadcast assigned to the function key is being broadcast from the equipment other than the Remote Microphone Lights yellow When a general BGM broadcast assigned to the function key is being broadcast from the primary RemoteMicrophone or other Remote Microphone 1 6 Indicator State at the Time of RM Broadcast Status Display The Broadcast status indicator t...

Страница 19: ...key causes all indicators on the primary Remote Microphone to light and the built in buzzer to sound Note For instructions on assigning functions to function keys see the separate Setting Software Instructions EVENT SETTINGS Lamp Test Indicator Function key Lamp test key Indicator meanings are as follows Indicator Status Meaning Lamp Test Indicator Unlit When the function key is not pressed Lights...

Страница 20: ...ction see the separate Setting Software Instructions BASIC SETTINGS For instructions on assigning functions to function keys see the separate Setting Software Instructions EVENT SETTINGS Key ON OFF Indicator Failure Output Receipt State Indicator Function key Failure output receipt key Indicator meanings are as follows Indicator Status Meaning Key ON OFF Indicator Unlit When the function key is no...

Страница 21: ...e indicator to the left of the key lights only when the key is pressed Notes For instructions on setting surveillance function see the separate Setting Software Instructions BASIC SETTINGS For instructions on assigning functions to function keys see the separate Setting Software Instructions EVENT SETTINGS Key ON OFF Indicator Always unlit not used Function key Failure Output Reset key Indicator m...

Страница 22: ...key and function keys see the separate Setting Software Instructions EVENT SETTINGS When assigned to the Emergency key Emergency key Indicator Status Meaning Emergency Key Indicator Unlit The VX 3000 system is not in an emergency condition Lights red The Emergency Broadcast Pattern is started by pressing this Emergency key or the VX 3000 system is in an emergency condition When assigned to the fun...

Страница 23: ...e key lights only when the key is pressed Notes For the emergency function settings see the separate Setting Software Instructions BASIC SETTINGS For instructions on assigning functions to the function keys see the separate Setting Software Instructions EVENT SETTINGS Key ON OFF Indicator Always unlit not used Function key Emergency broadcast pattern stop key Indicator meanings are as follows Indi...

Страница 24: ...or the emergency function settings see the separate Setting Software Instructions BASIC SETTINGS For instructions on assigning functions to the Emergency key and function keys see the separate Setting Software Instructions EVENT SETTINGS When assigned to the Emergency key Emergency key Indicator Status Meaning Emergency Key Indicator Unlit The VX 3000 system is not in an emergency condition Lights...

Страница 25: ...to the left of the key lights only when the key is pressed Notes For the emergency function settings see the separate Setting Software Instructions BASIC SETTINGS For instructions on assigning functions to the function keys see the separate Setting Software Instructions EVENT SETTINGS Key ON OFF Indicator Always unlit not used Function key Emergency sequence stop key Indicator meanings are as foll...

Страница 26: ...ate Setting Software Instructions BASIC SETTINGS For instructions on assigning functions to function keys see the separate Setting Software Instructions EVENT SETTINGS Key ON OFF Indicator Phase State Indicator Function key Phase shift key Indicator meanings are as follows Indicator Status Meaning Key ON OFF Indicator Unlit When the function key is not pressed Lights green When the function key is...

Страница 27: ...ncy function settings see the separate Setting Software Instructions BASIC SETTINGS For instructions on assigning functions to function keys see the separate Setting Software Instructions EVENT SETTINGS Restoration EV Message Status Indicator Key ON OFF Indicator Function key Emergency reset key Indicator meanings are as follows Indicator Status Meaning Key ON OFF Indicator Unlit When the function...

Страница 28: ...pending on the lighting statuses of the 2 indicators next to the Function key Notes For the emergency function settings see the separate Setting Software Instructions BASIC SETTINGS For instructions on assigning functions to the function key see the separate Setting Software Instructions EVENT SETTINGS The emergency broadcast silence function is valid only when the system is in the emergency mode ...

Страница 29: ...ions BASIC SETTINGS For instructions on assigning functions to the Emergency key and function keys see the separate Setting Software Instructions EVENT SETTINGS When assigned to the Emergency key Emergency key Indicator Status Meaning Emergency Key Indicator Unlit When the Emergency EV message assigned to the Emergency key is not broadcast to any zones Lights red When the Emergency EV message assi...

Страница 30: ...cy broadcast activation and emergency acknowledge status Notes For the emergency function settings see the separate Setting Software Instructions BASIC SETTINGS For instructions on assigning functions to the Emergency key and function keys see the separate Setting Software Instructions EVENT SETTINGS When assigned to the Emergency key Emergency key Indicator Status Meaning Emergency Key Indicator ...

Страница 31: ...etting Software that Emergency operation can be performed without pressing the emergency acknowledge key once the emergency broadcast pattern has been activated Indicator Status Emergency operation 1 Unlit enable disable indicator Meaning When set to EMG enable operation ON 2 Emergency operation from this remote microphone is disabled When set to EMG operation OFF 3 Constantly unlit Lights green E...

Страница 32: ...ction is assigned while the system is in emergency mode a beep tone will sound making the operation invalid Notes For the emergency function settings see the separate Setting Software Instructions BASIC SETTINGS For instructions on assigning functions to the function key see the separate Setting Software Instructions EVENT SETTINGS Status indicator of disablement of EMG control from CIN function K...

Страница 33: ...Control Input When an intended control input function has been assigned to a function key the 2 indicators to the left of the key indicate its selection and control status Note Operation may become invalid even if you press the function key when the Control status indicator is lighting This is such a case when the control input is placed in Active state by other device Wait until the Control statu...

Страница 34: ...s not activated Lights yellow When the Control output pattern assigned to this function key is being activated 1 23 Indicator State at the Time of Intended Control Output Level When the intended control output level function is assigned to the function key the preset control output is turned ON while this key is held down It is turned OFF when this key is released When an intended control output l...

Страница 35: ...ssed as long as it is pressed Volume Indicator Unlit In the case the set value 1 of the volume adjustment is positive volume increase When the current volume adjustment value of the zone assigned to this key is less than the initial value 2 In the case the set value 1 of the volume adjustment is negative volume decrease When the current volume adjustment value of the zone assigned to this key is g...

Страница 36: ...g as it is pressed Volume Indicator Unlit In the case the set value 1 of the volume adjustment is positive volume increase When the current volume adjustment value of the input channel assigned to this key is less than the initialvalue 2 In the case the set value 1 of the volume adjustment is negative volume decrease When the current volume adjustment value of the input channel assigned to this ke...

Страница 37: ...signed to the Emergency key is not broadcast to any zones Lights red When the audio source for an emergency warning broadcast assigned to the Emergency key is broadcast to at least a part of the zones assigned to this key When assigned to the function key Selection indicator Broadcast Status Indicator Function key Emergency warning broadcast key Indicator meanings are as follows Indicator Status M...

Страница 38: ... Selection key not in use or BGM broadcast in progress Flashes green A part of zones or the entire zone assigned to this Broadcast Zone Selection key is occupied by a broadcast from another device secondary Remote Microphone or general EV message or a part of zones is engaged by a broadcast from the primary Remote Microphone RM 300X Lights yellow All the zones selected by this Broadcast Zone Selec...

Страница 39: ...pressed Lights briefly then goes off Broadcast Status Indicator Unlit When the Base pattern assigned to the function key is not being broadcast Lights yellow When the Base pattern assigned to the function key is being broadcast including broadcasts activated by other devices Indicator Status Meaning Microphone Indicator Unlit Microphone not in use Lights green Microphone in use Flashes green Chime...

Страница 40: ...nstructions EVENT SETTINGS Selection indicator Broadcast Status Indicator Function key General BGM broadcast key Indicator meanings are as follows Indicator Status Meaning Selection Indicator Unlit When the function key is not pressed Lights green When the unit is brought in general BGM broadcast by pressing the function key Broadcast Status Indicator Unlit When a general BGM broadcast assigned to...

Страница 41: ...ot engaged in broadcasting Lights yellow When the Remote Microphone assigned to the function key is engaged in broadcasting 2 7 Indicator State at the Time of Lamp Test When the lamp test function has been assigned to the Function key the 2 indicators to the left of the key indicate the running status of the lamp test Pressing the Lamp Test key causes all indicators on the primary Remote Microphon...

Страница 42: ... function see the separate Setting Software Instructions BASIC SETTINGS For instructions on assigning functions to function keys see the separate Setting Software Instructions EVENT SETTINGS Key ON OFF Indicator Failure Output Receipt State Indicator Function key Failure output receipt key Indicator meanings are as follows Indicator Status Meaning Key ON OFF Indicator Unlit When the function key i...

Страница 43: ... indicator to the left of the key lights only when the key is pressed Notes For instructions on setting the surveillance function see the separate Setting Software Instructions BASIC SETTINGS For instructions on assigning functions to function keys see the separate Setting Software Instructions EVENT SETTINGS Key ON OFF Indicator Always unlit not used Function key Failure Output Reset key Indicato...

Страница 44: ...ng functions to the covered key and function keys see the separate Setting Software Instructions EVENT SETTINGS When assigned to the covered key Emergency Broadcast Indicator Lights red Cover Covered key Emergency key Indicator meanings are as follows Indicator Status Meaning Emergency Broadcast Indicator Unlit The VX 3000 system is not in an emergency condition Lights red The Emergency Broadcast ...

Страница 45: ...e key is pressed Notes For the emergency function settings see the separate Setting Software Instructions BASIC SETTINGS For the type of the RM 300X settings see the separate Setting Software Instructions Unit Configuration Settings For instructions on assigning functions to the function keys see the separate Setting Software Instructions EVENT SETTINGS Key ON OFF Indicator Always unlit not used F...

Страница 46: ...ndicator next to the key indicates the emergency condition of the VX 3000 system Meanwhile when a function key is assigned this function the 2 indicators next to the key indicate the emergency start and emergency states of the VX 3000 system Notes For the emergency function settings see the separate Setting Software Instructions BASIC SETTINGS For the type of the RM 300X settings see the separate ...

Страница 47: ... Stop When the system is set to Emergency and the type of the RM 300X to Emergency or Emergency General the emergency sequence stop function can be assigned to the Function key Pressing the function assigned key causes the emergency sequence to stop The indicator to the left of the key lights only when the key is pressed Notes For the emergency function settings see the separate Setting Software I...

Страница 48: ...GS For the type of the RM 300X settings see the separate Setting Software Instructions Unit Configuration Settings For instructions on assigning functions to function keys see the separate Setting Software Instructions EVENT SETTINGS Phase State Indicator Key ON OFF Indicator Function key Phase shift key Indicator meanings are as follows Indicator Status Meaning Key ON OFF Indicator Unlit When the...

Страница 49: ...mergency function settings see the separate Setting Software Instructions BASIC SETTINGS For the type of the RM 300X settings see the separate Setting Software Instructions Unit Configuration Settings For instructions on assigning functions to function keys see the separate Setting Software Instructions EVENT SETTINGS Key ON OFF Indicator Restoration EV Message State Indicator Function key Emergen...

Страница 50: ...tatuses of the 2 indicators next to the Function key Notes For the emergency function settings see the separate Setting Software Instructions BASIC SETTINGS For the type of the RM 300X settings see the separate Setting Software Instructions Unit Configuration Settings For instructions on assigning functions to the function key see the separate Setting Software Instructions EVENT SETTINGS The emerg...

Страница 51: ...Instructions Unit Configuration Settings For instructions on assigning functions to the covered key and function keys see the separate Setting Software Instructions EVENT SETTINGS When assigned to the covered key Emergency Broadcast Indicator Lights red Cover Covered key Emergency key Indicator meanings are as follows Indicator Status Meaning Emergency Broadcast Indicator Unlit When the Emergency ...

Страница 52: ...ion settings see the separate Setting Software Instructions BASIC SETTINGS For the type of the RM 300X settings see the separate Setting Software Instructions Unit Configuration Settings For instructions on assigning functions to the Emergency key and function keys see the separate Setting Software Instructions EVENT SETTINGS When assigned to the covered key Emergency Broadcast Indicator Lights re...

Страница 53: ...etting Software that Emergency operation can be performed without pressing the emergency acknowledge key once the emergency broadcast pattern has been activated Indicator Status Emergency operation 1 Unlit enable disable indicator Meaning When set to EMG enable operation ON 2 Emergency operation from this remote microphone is disabled When set to EMG operation OFF 3 Constantly unlit Lights green E...

Страница 54: ...he system is in emergency mode a beep tone will sound making the operation invalid Notes For the emergency function settings see the separate Setting Software Instructions BASIC SETTINGS For the type of the RM 300X settings see the separate Setting Software Instructions Unit Configuration Settings For instructions on assigning functions to the function key see the separate Setting Software Instruc...

Страница 55: ...ontrol Input When an intended control input function has been assigned to a function key the 2 indicators to the left of the key indicate its selection and control statuses Note Operation may become invalid even if you press the function key when the Control status indicator is lighting This is such a case when the control input is placed in Active state by other device Wait until the Control stat...

Страница 56: ...s not activated Lights yellow When the Control output pattern assigned to this function key is being activated 2 23 Indicator State at the Time of Intended Control Output Level When the intended control output level function is assigned to the function key the preset control output is turned ON while this key is held down It is turned OFF when this key is released When an intended control output l...

Страница 57: ...ssed as long as it is pressed Volume Indicator Unlit In the case the set value 1 of the volume adjustment is positive volume increase When the current volume adjustment value of the zone assigned to this key is less than the initial value 2 In the case the set value 1 of the volume adjustment is negative volume decrease When the current volume adjustment value of the zone assigned to this key is g...

Страница 58: ...g as it is pressed Volume Indicator Unlit In the case the set value 1 of the volume adjustment is positive volume increase When the current volume adjustment value of the input channel assigned to this key is less than the initialvalue 2 In the case the set value 1 of the volume adjustment is negative volume decrease When the current volume adjustment value of the input channel assigned to this ke...

Страница 59: ...adcast Indicator Unlit When the audio source for an emergency warning broadcast assigned to the Emergency key is not broadcast to any zones Lights red When the audio source for an emergency warning broadcast assigned to the Emergency key is broadcast to at least a part of the zones assigned to this key When assigned to the function key Selection indicator Broadcast Status Indicator Function key Em...

Страница 60: ...Chapter 3 OPERATION ...

Страница 61: ...ne selection individual Function key R5 Zone clear Clear pre selected zones Function key R6 General broadcast pattern 1 Activation and end of general broadcast pattern 1 broadcast Function key R7 General EV broadcast Activation and end of general BGM broadcast Function key R8 Zone 1 volume up Zone volume adjustment pulse Function key R9 Zone 1 volume down Zone volume adjustment pulse Function key ...

Страница 62: ...le through the monitor speaker built in the RM 300X The Microphone indicator flashes green while the chime is being activated Note Pressing the Talk key again while the chime is being activated causes the chime to stop ending the broadcast in progress Step 3 When the microphone indicator next to the Talk key lights green make the microphone announcement The zones assigned to Function keys R2 R4 ar...

Страница 63: ... the Talk key A chime will be broadcast This chime will be audible through the monitor speaker built in the RM 300X The Microphone indicator flashes green while the chime is being activated Note Pressing the Talk key again while the chime is being activated causes the chime to stop ending the broadcast in progress Step 3 When the microphone indicator next to the Talk key lights green make the micr...

Страница 64: ... Press the Talk key Zones preset to the Talk key will be selected and a chime will be broadcast This chime willbe audible through the monitor speaker built in the RM 300X Broadcast status indicator Microphone indicator Talk key The Microphone indicator flashes green while the chime is being activated Note Pressing the Talk key again while the chime is being activated causes the chime to stop endin...

Страница 65: ...ed After the pattern selection indicator next to Function key L2 lights green then goes off the broadcast status indicator lights yellow The broadcast status indicator next to Function key L1 goes off Step 3 Press the Function key L3 BGM end BGM ends All indicators go off 1 3 5 Example of general broadcasting Step 1 Press the Function key R6 General broadcast pattern 1 General broadcast pattern 1 ...

Страница 66: ...es green Lights yellow Green Function key R7 General EV broadcast 1 3 7 Example of zone volume adjustment When increasing the volume level of the preset zone Step Press the function key R8 Zone 1 volume up several times until the volume becomes the desired level Each time the key is pressed the volume level of the set zone or that of the zone pattern increases by the set amount The volume indicato...

Страница 67: ... the initial value of that input channel When decreasing the volume level of the preset input channel Step Press the function key 12 Input 1 volume down several times until the volume becomes the desired level Each time the key is pressed the volume level of the set input channel decreases by the set amount The volume indicator lights green when the volume level becomes smaller than the initial va...

Страница 68: ... will override the general broadcast while left in the general mode When the emergency warning broadcast is activated while the higher priority broadcast is in progress the emergency warning broadcast is placed in standby and will start after the higher priority broadcast is complete Operation example for the emergency warning broadcast The example below shows the operation procedure when the Emer...

Страница 69: ...broadcast to the entire zone Alert and Evacuation Message Examples Alert Message The fire alarm system has been engaged We are now checking the cause Please wait for further information Evacuation Message There is a fire Please evacuate immediately GF 1F 2F 3F General purpose broadcast mode Emergency sequence Phase 1 5 minutes BGM GF Building A Building B 1F 2F 3F 4F 5F 6F BGM GF 1F 2F 3F BGM GF B...

Страница 70: ...rregularities and the fire alarm system transmits a control signal to the control input Broadcast zones are added and the alert message is also broadcast to A 2F and A 4F as well Step 4 After the set 5 minute time interval elapses the message is automatically switched from Phase 1 to Phase 2 Broadcast zones change to the entire zone and the evacuation message is broadcast to the entire area and BG...

Страница 71: ...tes Phase 2 Evacuation message all zones continuous 2 Emergency Sequence Phase Shift Shifts the phase of the sequence pattern currently being broadcast to the next phase 3 Emergency Reset Restoration message Broadcast is restored from emergency to normal general purpose broadcast mode after Restoration message announcement completion 4 All Zone Call Selects all zones 5 Press to Talk Makes micropho...

Страница 72: ...rgency sequence phase 1 is broadcast Phase state indicator Key ON OFF indicator Phase Shift key Green Step 2 Press the Emergency Phase Shift key 2 to broadcast the Evacuation message if necessary The Evacuation message will be broadcast to all zones In this event the broadcast pattern shifts from the emergency sequence phase 1 to the phase 2 and the Phase state indicator flashes green The Zone mon...

Страница 73: ...en a Fireman s Microphone announcement interrupts a message broadcast the broadcast mode that follows Fireman s Microphone announcement completion can be set to either Continue for continuous EV message broadcast or Silent for broadcast termination This setting can be made by using the VX 3000 Setting Software Step 4 Terminate the Emergency status Press the Emergency Reset key 3 The restoration me...

Страница 74: ...oadcast status indicator lights red Zone monitor indicator Selection indicator Emergency EV broadcast status indicator Key ON OFF indicator Emergency EV Flashes red Zone Selection key Broadcast key Green Red Green Operation example 3 Example of emergency acknowledge When the emergency broadcast pattern is activated the buzzer built in the remote microphone sounds and the Emergency broadcast status...

Страница 75: ...trol from CIN key Operation example 5 Example of disablement of EMG control from CIN Operation when the function is turned ON by other remote microphone When the Disablement of EMG control from CIN key is assigned to 2 or more remote microphones function keys the buzzer will sound and the status indicator of disablement of EMG control from CIN function will flash red if this function is turned ON ...

Страница 76: ...th the same priory overlap they are mixed and output Connection destination with the highest priority RS LINK A terminal of the VX 3308WM set to ID 0 Connection destination with 2nd highest priority RS LINK B terminal of the VX 3308WM set to ID 0 Connection destination with 3rd highest priority RS LINK A and B terminals of the VX 3308WM set to ID other than 0 First priority RS LINK A RS LINK B VX ...

Страница 77: ...ts red and begin to make microphone announcements Failure Indicator Lights red Cover All zone Emergency Broadcast key Notes The RM 300X s DIP switch 5 factory default ON must be preset to ON to enable the CPU OFF function all zone emergency broadcast The event being activated from the remote microphone will be cleared when the system is placed in the CPU OFF state and not restarted when its state ...

Страница 78: ...dcast The event being activated from the remote microphone will be cleared when the system is placed in the CPU OFF state and not restarted when its state is released RM 200SF rear Step 2 Make the microphone announcement while holding down the Talk key Talk key Step 3 When the microphone announcement is complete return the CPU switch to ON RM 200SF FIREMAN S MICROPHONE CPU OFF MIC SP CPU OFF ON DI...

Страница 79: ...08WM Function keys on the RM 300X or RM 200SF Note Regarding the setting procedures for detecting fault within the VX 3308WM see the separate Setting Software Instructions BASIC SETTINGS 5 1 Fault Detection Setting Example The method to detect the fault within the system using the VX 3308WM RM 200SF and RM 320F is described below System configuration RM 200SF RM 320F VX 3308WM GF 1F 2F BGM Player ...

Страница 80: ...unction The example here assumes that the speaker terminal for the Zone 2F is disconnected VX 3308WM 1F 2F GF ZONE 1F ZONE 2F ZONE GF RS LINK AUDIO INPUT 1 AUDIO INPUT 2 Fault Key Set function 1 Not set 2 Talk key fixed 3 Zone Clear 4 Failure Output Reset 5 Lamp Test Key Set function Contents failure pattern 6 Failure Output Receipt VX 3308WM 7 Failure Output Receipt Amplifier ZONE GF 8 Failure Ou...

Страница 81: ...t the speaker terminal for the zone 2F is open state is listed then fix the fault part Note Operation of failure indication differs depending on which the Failure indication setting is set to Auto reset or Manual reset on the VX 3000 Setting Software When set to Auto reset For most failure indications the failure LED automatically goes off when the cause has been corrected For certain other failur...

Страница 82: ...then remove it Connect a PC to the VX 3308WM and read out the log data using the VX 3000 Setting Software For details see the separate Setting Software Instructions Maintenance Confirm the cause of failure or abnormality on the log data in this example the log data that the speaker terminal for the zone 2F is open state is listed then fix the fault part Note Operation of failure indication differs...

Страница 83: ... key 5 5 Example of Executing the Failure Reception and Failure Reset by Way of the Control Input Terminals Assign the failure reception and failure reset functions to the control input terminals on the rear panel of the VX 3308WM in advance For details see the separate software instruction manual EVENT SETTINGS Short each function assigned terminals with a one shot pulse Short Over 0 1 seconds ...

Страница 84: ...parate Setting Software Instructions EVENT SETTINGS CPU indicator Step 1 Continuously press the Lamp Test key 5 All the indicators except the CPU indicator light and the buzzer built in the RM 200SF sounds Step 2 Confirm that the indicators and speaker operate correctly as in Step 1 Step 3 Release the Lamp Test key 5 to finish the lamp test Key Set function 1 Not set 2 Talk key fixed 3 Zone Select...

Страница 85: ... the Lamp test key All indicators light dose not include AC power in and battery LED indicator and the buzzer built in the VX 3308WM sounds VX 3308WM Step 2 Confirm that the indicators and buzzer operate correctly as in Step 1 Step 3 Release the Lamp test key to finish the lamp test VX ...

Страница 86: ...ored by the remote microphone Step 1 Press the Audio monitor key The Broadcast status indicator lights green while audio signals are broadcast to the zone assigned to this function key Audio signals being broadcast in the zone assigned to the Audio monitor key are output from the remote microphone Notes No broadcast is output to the zone assigned to the Audio monitor key when the Broadcast status ...

Страница 87: ...status indicator is unlit The Control output pattern assigned to the Intended control output pulse key is activated and the Control status indicator lights yellow Note Operation is invalid even if you press the Intended control output pulse key when the Control status indicator is lighting yellow though its key is not pressed This is such a case when the control output pattern is being activated b...

Страница 88: ...key is activated and the Control status indicator lights yellow Note Operation is invalid even if you press the Intended control output level key when the Control status indicator is lighting yellow though its key is not pressed This is such a case when the control output pattern is being activated by other Event Step 2 To stop the control output pattern activation release the Intended control out...

Страница 89: ...mation for Europe Manufacturer TOA Corporation 7 2 1 Minatojima Nakamachi Chuo ku Kobe Hyogo Japan Authorized representative TOA Electronics Europe Gmbh Suederstrasse 282 20537 Hamburg Germany 201812 URL http www toa jp ...

Отзывы: