background image

OPERATION

Set a clock for 08:55.

HOUR

MIN.

MIN.

(one  hour's digit)

(Ten minute's digit)

(one minute's digit)

Press the HOUR key (one hour's digit) 8 times.

The clock display shows "0800".

Press the MIN. key (ten minute's digit) 5 times.

The clock display shows "0850".

Press the MIN. key (one minute's digit) 5 times.

The clock display shows "0855".

Register the  hour 08:55.
Press the STORE key.

STORE

(The content of the program is not stored without pressing the STORE key.)

The word "PASS" appears in the clock display, indicating the

hour 08:55 has been  registered into the A output channel.

Repeat steps

and

to register all the hours from 09:00 to 17:30.

Pressing the STORE key to register the unreal hour other than one from 00:00 to 23:59

causes characters "Err" to appear in the clock display and the attempt of its registration is

refused. Correct the hour and  register it again.

When one same hour is registered twice, characters "Err" are indicated in the clock display.

If a registration attempt is made in excess of the program capacity (30), the word "End"

appears in the clock display,  refusing the registration.

Repeat steps

through

to register days of the week and hours into both B and C channels.

PROGRAM CHECK, CORRECTION AND CANCELLATION

After finishing  program  registrations, check the program contents.

Shift the program switch back to PROGRAM.

OPERATION

PROGRAM

The output indicators of A, B, C and D channels as well as the

pause indicator comes on.

9

Содержание TT-104

Страница 1: ...ancellation can be performed easily and precisely through individual key operation and display Setting the pause mode allows no program output to be delivered Output is a no voltage make contact that...

Страница 2: ...Program registration 4 Program check correction and cancellation 5 Entire program cancellation 6 Program operation 7 Pause mode 8 Using front mounted AUTO OFF switch 9 Using manual switch 10 Using rea...

Страница 3: ...icator Clock setting keys Use this keys to set a clock for the current hour To do this press this setting with the ADJUST key pressed continuously This setting is also used to set the time of the time...

Страница 4: ...n label This label is supplied with unit Write the names of programs of or equipment connected to each output channel in the label STORE key Press this key to store the day of the week or hours set un...

Страница 5: ...art terminals of BGM player or spot announcing machine etc MEMORY BACK UP switch Be sure to set this switch to ON after installation This switch protects clock and stored programs for approximately 10...

Страница 6: ...ed If the unreal hour is set which is not in a range from zero hour 00 00 to 23 hundred 59 hours 23 59 both the date indicator and clock display flash and at the same time a warning tone beeps In such...

Страница 7: ...programs together per equipment connected and assign the output channel to each equipment If the same equipment are used but their programs are not the same assign different output channels Example If...

Страница 8: ...setting Its indicator comes on Press the THU setting Its indicator comes on Press the FRI setting Its indicator comes on MON TUE WED THU FRI When the wrong day setting has been pressed press the same...

Страница 9: ...9 00 to 17 30 Pressing the STORE key to register the unreal hour other than one from 00 00 to 23 59 causes characters Err to appear in the clock display and the attempt of its registration is refused...

Страница 10: ...day of the week To step 10 to cancel the day of the week Press the TIME mode key The time mode indicator comes on and at the same time a dotted line flashes in the clock display Check the hour Each t...

Страница 11: ...till that hour appears in the display Press the CANCEL key for cancelling the indicated hour and then set the new hour using the clock settings Register the new hour with the STORE key Be sure to canc...

Страница 12: ...ION PROGRAM PAUSE MODE The PAUSE key is used to temporarily make the timer not to function on particular days This is possible for up to the 7th day from the day of registration No output is delivered...

Страница 13: ...nt day is set after the pause registration perform the new pause registration Set the program switch to OPERATION after finishing programing USING FRONT MOUNTED AUTO OFF This switch is used to stop ac...

Страница 14: ...t is delivered from each channel as follows A 8 30 9 30 10 30 B 9 00 10 00 11 00 C 12 00 If all the switches are set to OFF A channel Output is delivered at 8 30 9 30 and 10 30 B channel Output is del...

Страница 15: ...chool hour program 4 Examination day program 1 register the ordinary school hour program into the A channel Register Monday through Friday 2 register the Saturday program into the B channel Register S...

Страница 16: ...dications go out at time of power outage However a clock works normally and stored programs are protected No relay output is produced After power restoration the timer works normally and indicates the...

Страница 17: ...50 60 Hz 3 watts 100 hours 30 steps per channel Day of the week hour minute output channel 4 channels A B C D No voltage dry make contact 5 seconds make output 24 V DC 0 5 A 5 seconds per month 25 C...

Страница 18: ...TOA Corporation Printed in Japan 133 05 276 50...

Отзывы: