Table 3. CHANNELS VS FUNCTIONS FOR CP-63
CHANNEL SELECTION
CH.
0
CH. 1
CH. 2
CH. 3
Note.
*1. Each exchange has an independent control system, and it is
impossible to control the Data Transmitting Unit of the other
exchange from the station connected to the different exchange.
*2. Can only be connected to the exchange A (Station No. 200 ~
327). It is impossible to call the pagers from any station not
connected to the exchange A. However, the response to a pager
call is possible from any station regardless of the exchange it is
connected to.
— 44 —
FUNCTIONS
DESCRIPTION
APPLICATION
IN/OUT Annunciation
Personel in and out registration can
be accomplished at any Master sta-
tion by using personal numbers. Max.
500 IN/OUT annunciations may be
done. ( A l l the 3 exchanges provided
the same indication)
IN/OUT Annunciation
( 1 ) One-shot Make Output
(50 contacts)
(2) Make/Break Output
(100 contacts)
(3) 8 Selectable Make Output
(9 unit blocks)
One contact out of 8 selectable make
outputs is obtained. "Clear" opera-
tion makes all 8 relays break. *1
Make/Break contacts can be available
at any Master station. *1
One-shot make contacts can be avail-
able at any Master station. *1
ITV camera selection
VTR control
Door Remote
IN/OUT Annunciation
Destination indication
VTR control
(5) 4 Decimal digits output
(9 unit blocks)
(4) Decimal Output
(9 unit blocks)
10 Selectable Decimal Outputs are
available with 7 segments LEDs. *1
Room condition indication.
Prescription annunciation
Pager
The group number of called
station(s). No. 1 ~ 4
The group number of called
station(s). No. 5 ~ 8
Indicate by 7 segments LEDs. *1
Make output (64 contacts) are avail-
able for pager control. *2
(6) Pager Control Output
(64 contacts)
Calling Party Indication ( 1 )
(One Station; One Lamp)
Calling Party Indication (2)
(One Station; One Lamp)
Max. 120-Calling station numbers can
be indicated when designated called
station with Display Board is called.
The numbers of called stations having
an indication panel can be program-
med at No. 200 station. (Only the
calling
stations within the same
exchange can be indicated by a lamp)
Содержание EXES-6000
Страница 1: ...TOA EXES 6000 SYSTEM TOA Corporation KOBE JAPAN...
Страница 13: ...1 Voice Signal Flow Fig 15 Voice Signal Flow 10 II VOICE SIGNAL AND DIAL SIGNAL FLOWS...
Страница 18: ...15 Fig 19 Voice and Dial Signal Flows 16...
Страница 31: ...Fig 32 Zone Paging Signal Flow 29...
Страница 32: ...Fig 33 All Call Paging Signal Flow 30...
Страница 33: ...Fig 34 Station Paging Zone Assignment EX 630 31 32 2 Connection for Station Paging Group Paging...
Страница 39: ...EXCHANGE A No 200 327 EXCHANGE B No 470 597 38 39...
Страница 47: ...Fig 41 System Block Diagram of Data Transmitting and Receiving Units in CP 6 4 System 47...
Страница 50: ...Fig 44 Contents of Data from CPU and Conversion Process into Transmitting Signal FSK 50...
Страница 60: ...TOA Corporation KOBE JAPAN No 833 72 051 30 EGA09101100E Printed in Japan...