The serial pulse streams that went into IP No. 0
are transmitted to both the OC unit and HC unit
after being converted into parallel codes. In the
HC unit, the data from the CP unit is written into
both the line memory and signal memory accord-
ing to the address specified by the OC unit.
Station numbers of the stations in converstations
and the status of each link are written in the line
memory, of which contents become the control
signals for the analog switches of the LM unit.
Signal codes, PIT or non-PTT mode and the
status of each link are written in the signal
memory, of which contents become the control
signals for the analog switches of the SG unit.
— 14 —