background image

 

172-65176MA-03  (UFO3 Series)  27  Aug 2015

 

2

 

Safety Considerations 

  Read this section carefully before use and be sure to follow the 

instructions. 

  Installation, inspection, maintenance, repairs, disassembly, adjustment and 

valve opening/closing should be carried out only by trained maintenance 
personnel

.

 

  The precautions listed in this manual are designed to ensure safety and 

prevent equipment damage and personal injury. For situations that may 
occur as a result of erroneous handling, three different types of cautionary 
items are used to indicate the degree of urgency and the scale of potential 
damage and danger: DANGER, WARNING and CAUTION. 

  The three types of cautionary items above are very important for safety: be 

sure to observe all of them as they relate to installation, use, maintenance, 
and repair. Furthermore, TLV accepts no responsibility for any accidents or 
damage occurring as a result of failure to observe these precautions. 

Symbols 

 

Indicates a DANGER, WARNING or CAUTION item. 

 

DANGER 

 

Indicates an urgent situation which poses a threat of death or 
serious injury 

 

WARNING 

 

Indicates that there is a potential threat of death or serious injury 

 

CAUTION 

 

Indicates that there is a possibility of injury or equipment / product 
damage 

 

 

CAUTION 

 

Install properly and DO NOT use this product outside the 
recommended operating pressure, temperature and other 
specification ranges. 

Improper use may result in such hazards as damage to the 
product or malfunctions that may lead to serious accidents. Local 
regulations may restrict the use of this product to below the 
conditions quoted. 

 

DO NOT use this product in excess of the maximum operating 
pressure differential.

 

 

Such use could make discharge impossible (blocked).

 

 

Take measures to prevent people from coming into direct 
contact with product outlets. 

Failure to do so may result in burns or other injury from the 
discharge of fluids.

 

 

When disassembling or removing the product, wait until the 
internal pressure equals atmospheric pressure and the 
surface of the product has cooled to room temperature

Disassembling or removing the product when it is hot or under 
pressure may lead to discharge of fluids, causing burns, other 
injuries or damage.

 

Safety considerations continued on next page. 

Содержание UFO3-BN

Страница 1: ...03 UFO3 Series 27 August 2015 Free Ball Bucket Steam Trap UFO3 BN UFO3F BN Copyright 2015 by TLV CO LTD All rights reserved ISO 9001 ISO 14001 Manufacturer Kakogawa Japan is approved by LRQA LTD to IS...

Страница 2: ...is out of the ordinary Also be sure to read this manual carefully before use and follow the instructions to be sure of using the product properly The Free Ball Bucket Steam Trap is suitable for appli...

Страница 3: ...ation which poses a threat of death or serious injury WARNING Indicates that there is a potential threat of death or serious injury CAUTION Indicates that there is a possibility of injury or equipment...

Страница 4: ...fluids Do not use excessive force when connecting threaded pipes to the product Over tightening may cause breakage leading to fluid discharge which may cause burns or other injury Use only under condi...

Страница 5: ...to back pressure has a check valve TLV CK been installed 5 Is the inlet pipe as short as possible with as few bends as possible and installed so the liquid will flow naturally down into the trap 6 Ha...

Страница 6: ...reventing it from closing against the drain jet allowing the discharge of all initial air and cold condensate 2 Entry of Steam When steam flows in the higher temperature causes the bimetal to expand r...

Страница 7: ...ION Refer to the product nameplate for detailed specifications Model Maximum Allowable Temperature TMA Maximum Allowable Pressure Maximum Operating Temperature Nominal Diameter Maximum Differential Pr...

Страница 8: ...use burns or other injury CAUTION Installation inspection maintenance repairs disassembly adjustment and valve opening closing should be carried out only by trained maintenance personnel 1 Before inst...

Страница 9: ...e to steam leakage Normal Condensate together with flash steam is discharged intermittently and the sound of flow can be heard at the time of discharge Blocked Discharge Impossible No condensate is di...

Страница 10: ...re no pieces of the old gasket left on the seating surfaces make sure the arrow points in the direction of condensate flow Cover Gasket Remove being careful not to damage the seating surface and clean...

Страница 11: ...1 N m 10 kg cm NOTE Coat all threaded portions and orifice gasket with anti seize If drawings or other special documentation were supplied for the product any torque given there takes precedence over...

Страница 12: ...ns Steam locking has occurred Perform a bypass blowdown or close the trap inlet piping and allow the trap to cool Steam is discharged or leaks from the outlet blowing steam leakage Build up of rust or...

Страница 13: ...proper installation use handling etc by other than TLV CO LTD authorized service representatives 2 Malfunctions due to dirt scale rust etc 3 Malfunctions due to improper disassembly and reassembly or...

Страница 14: ...ection maintenance repairs disassembly adjustment and valve opening closing should be carried out only by trained maintenance personnel Attaching the Insulation Cover to the Steam Trap 1 Allow the tra...