172-65176MA-03 (UFO3 Series) 27 August 2015
Free Ball-Bucket Steam Trap
UFO3-BN
•
UFO3F-BN
Copyright © 2015 by TLV CO., LTD.
All rights reserved
ISO 9001/ ISO 14001
Manufacturer
Kakogawa, Japan
is approved by LRQA LTD. to ISO 9001/14001
Страница 1: ...03 UFO3 Series 27 August 2015 Free Ball Bucket Steam Trap UFO3 BN UFO3F BN Copyright 2015 by TLV CO LTD All rights reserved ISO 9001 ISO 14001 Manufacturer Kakogawa Japan is approved by LRQA LTD to IS...
Страница 2: ...is out of the ordinary Also be sure to read this manual carefully before use and follow the instructions to be sure of using the product properly The Free Ball Bucket Steam Trap is suitable for appli...
Страница 3: ...ation which poses a threat of death or serious injury WARNING Indicates that there is a potential threat of death or serious injury CAUTION Indicates that there is a possibility of injury or equipment...
Страница 4: ...fluids Do not use excessive force when connecting threaded pipes to the product Over tightening may cause breakage leading to fluid discharge which may cause burns or other injury Use only under condi...
Страница 5: ...to back pressure has a check valve TLV CK been installed 5 Is the inlet pipe as short as possible with as few bends as possible and installed so the liquid will flow naturally down into the trap 6 Ha...
Страница 6: ...reventing it from closing against the drain jet allowing the discharge of all initial air and cold condensate 2 Entry of Steam When steam flows in the higher temperature causes the bimetal to expand r...
Страница 7: ...ION Refer to the product nameplate for detailed specifications Model Maximum Allowable Temperature TMA Maximum Allowable Pressure Maximum Operating Temperature Nominal Diameter Maximum Differential Pr...
Страница 8: ...use burns or other injury CAUTION Installation inspection maintenance repairs disassembly adjustment and valve opening closing should be carried out only by trained maintenance personnel 1 Before inst...
Страница 9: ...e to steam leakage Normal Condensate together with flash steam is discharged intermittently and the sound of flow can be heard at the time of discharge Blocked Discharge Impossible No condensate is di...
Страница 10: ...re no pieces of the old gasket left on the seating surfaces make sure the arrow points in the direction of condensate flow Cover Gasket Remove being careful not to damage the seating surface and clean...
Страница 11: ...1 N m 10 kg cm NOTE Coat all threaded portions and orifice gasket with anti seize If drawings or other special documentation were supplied for the product any torque given there takes precedence over...
Страница 12: ...ns Steam locking has occurred Perform a bypass blowdown or close the trap inlet piping and allow the trap to cool Steam is discharged or leaks from the outlet blowing steam leakage Build up of rust or...
Страница 13: ...proper installation use handling etc by other than TLV CO LTD authorized service representatives 2 Malfunctions due to dirt scale rust etc 3 Malfunctions due to improper disassembly and reassembly or...
Страница 14: ...ection maintenance repairs disassembly adjustment and valve opening closing should be carried out only by trained maintenance personnel Attaching the Insulation Cover to the Steam Trap 1 Allow the tra...