Maintenance 

 

 

Take measures to prevent people from coming into direct contact with 

product outlets. Failure to do so may result in burns or other injury from 

the discharge of fluids.

 

CAUTION 

 

 

Be sure to use only the recommended components when repairing the 

product, and NEVER attempt to modify the product in any way. Failure to 

observe these precautions may result in damage to the product or burns 

or other injury due to malfunction or the discharge of fluids.

 

CAUTION 

 

Operational Check 

A visual inspection of the following items should be done on a daily basis to determine 
whether the trap is operating properly or has failed. Periodically (at least biannually) 
the operation should also be checked by using diagnostic equipment, such as a 
stethoscope, thermometer or TLV Pocket TrapMan or TLV TrapMan. 

If the trap should fail, it may cause damage to piping and equipment, resulting in 
faulty or low quality products or losses due to steam leakage.   

Normal                         

:  Condensate, together with flash steam, is discharged intermittently, 

and the sound of flow can be heard at the time of discharge.   

Blocked                     
(Discharge Impossible) 

:  No condensate is discharged. The trap is quiet and makes no noise, 

and the surface temperature of the trap is low. 

Blowing                       

:  Live steam continually flows from the outlet and there is a 

continuous metallic sound.   

Steam Leakage   

:  Live steam is discharged through the trap outlet together with 

condensate, accompanied by a high-pitched sound. 

(When conducting a visual inspection, flash steam is sometimes mistaken for steam leakage. For 
this reason, the use of a steam trap diagnostic instrument [TLV: TrapMan] in conjunction with the 
visual inspection is highly recommended.) 

 

Flash Steam 

Live Steam Leakage 

 

 

Parts Inspection 

When parts have been removed, or during periodic inspections, use the following 
table to inspect the parts and replace any that are found to be defective. 

Procedure

 

Gaskets: check for warping or scratches 
Screen: check for clogging or corrosion 
Drain-jet: Check for damage 
UFO Ball-bucket: check for scratches or dents 

White jet 

containing 

water droplets

 

Clear, slightly 

bluish jet

 

Содержание UFO3-BN

Страница 1: ...03 UFO3 Series 27 August 2015 Free Ball Bucket Steam Trap UFO3 BN UFO3F BN Copyright 2015 by TLV CO LTD All rights reserved ISO 9001 ISO 14001 Manufacturer Kakogawa Japan is approved by LRQA LTD to IS...

Страница 2: ...is out of the ordinary Also be sure to read this manual carefully before use and follow the instructions to be sure of using the product properly The Free Ball Bucket Steam Trap is suitable for appli...

Страница 3: ...ation which poses a threat of death or serious injury WARNING Indicates that there is a potential threat of death or serious injury CAUTION Indicates that there is a possibility of injury or equipment...

Страница 4: ...fluids Do not use excessive force when connecting threaded pipes to the product Over tightening may cause breakage leading to fluid discharge which may cause burns or other injury Use only under condi...

Страница 5: ...to back pressure has a check valve TLV CK been installed 5 Is the inlet pipe as short as possible with as few bends as possible and installed so the liquid will flow naturally down into the trap 6 Ha...

Страница 6: ...reventing it from closing against the drain jet allowing the discharge of all initial air and cold condensate 2 Entry of Steam When steam flows in the higher temperature causes the bimetal to expand r...

Страница 7: ...ION Refer to the product nameplate for detailed specifications Model Maximum Allowable Temperature TMA Maximum Allowable Pressure Maximum Operating Temperature Nominal Diameter Maximum Differential Pr...

Страница 8: ...use burns or other injury CAUTION Installation inspection maintenance repairs disassembly adjustment and valve opening closing should be carried out only by trained maintenance personnel 1 Before inst...

Страница 9: ...e to steam leakage Normal Condensate together with flash steam is discharged intermittently and the sound of flow can be heard at the time of discharge Blocked Discharge Impossible No condensate is di...

Страница 10: ...re no pieces of the old gasket left on the seating surfaces make sure the arrow points in the direction of condensate flow Cover Gasket Remove being careful not to damage the seating surface and clean...

Страница 11: ...1 N m 10 kg cm NOTE Coat all threaded portions and orifice gasket with anti seize If drawings or other special documentation were supplied for the product any torque given there takes precedence over...

Страница 12: ...ns Steam locking has occurred Perform a bypass blowdown or close the trap inlet piping and allow the trap to cool Steam is discharged or leaks from the outlet blowing steam leakage Build up of rust or...

Страница 13: ...proper installation use handling etc by other than TLV CO LTD authorized service representatives 2 Malfunctions due to dirt scale rust etc 3 Malfunctions due to improper disassembly and reassembly or...

Страница 14: ...ection maintenance repairs disassembly adjustment and valve opening closing should be carried out only by trained maintenance personnel Attaching the Insulation Cover to the Steam Trap 1 Allow the tra...