Condensate
Reservoir
Pi
PowerTrap
②
When flash steam is not involved
(For closed systems)
Determining the reservoir diameter and
length based on the amount of Condensate:
300 or less
400
500
600
800
1000
1500
2000
3000
4000
5000
6000
7000
8000
9000
10000
Amount of
Condensate
(kg/h)
Reservoir Diameter (mm) & Length (m)
Reservoir Diameter (in) & Length (ft)
500 or less
700
1000
1200
1500
2000
3000
4000
5000
6000
7000
8000
9000
10000
12000
14000
16000
18000
20000
Amount of
Condensate
(lb/h)
40
1.2m
1.5
2.0
50
0.7
1.0
1.2
1.5
2.0
80
0.5
0.6
0.8
1.0
1.5
2.0
100
0.5
0.7
1.0
1.3
2.0
150
0.6
0.9
1.2
1.4
1.7
2.0
200
0.5
0.7
0.8
1.0
1.2
1.3
1.5
1.7
250
0.5
0.6
0.7
0.8
0.9
1.0
1
3.0 ft
4.0
5.5
2
2.0
2.5
3.5
4.5
3
1.0
1.5
2.0
2.5
3.5
4.5
6.5
4
1.0
1.5
2.0
3.0
4.0
5.0
5.5
6.5
6
1.5
2.5
2.5
3.0
3.5
4.0
4.5
5.0
6.0
6.5
8
1.5
1.5
2.0
2.5
2.5
3.0
3.5
4.0
4.5
1.5
10
1.5
1.5
2.0
2.5
2.5
3.0
1.5
NOTE: Reservoir length can be reduced by 50% when the motive pressure (Pm) divided by the
back pressure (P
b
) is "2" or greater. (When Pm ÷ P
b
≥
2)
③
When there are small quantities of flash steam and a large amount of condensate
(E.g., open systems pumping large amounts of super-cooled condensate)
Consult the sizing tables in sections
①
and
②
above.
Select the condensate receiver size based on the larger of
①
and
②
.
Select the vent pipe diameter and overflow pipe diameter from
①
.
Reservoir Table
(For equalized, closed system installations)
/
1 2
— 16 —