background image

 

172-65286MA-03  (DC3S-L)    6  Oct  2021

 

Installation 

 

 

Install properly and DO NOT use this product outside the recommended 

operating pressure, temperature and other specification ranges. 

Improper use may result in such hazards as damage to the product or 

malfunctions which may lead to serious accidents. Local regulations 

may restrict the use of this product to below the conditions quoted.

 

CAUTION 

 

 

Use hoisting equipment for heavy objects (weighing approximately 

20 kg (44 lb) or more). Failure to do so may result in back strain or other 

injury if the object should fall. 

CAUTION 

 

 

Take measures to prevent people from coming into direct contact with 

product outlets. Failure to do so may result in burns or other injury from 

the discharge of fluids.

 

CAUTION 

 

 

Do not use excessive force when connecting threaded pipes to the 

product. Over-tightening may cause breakage leading to fluid 

discharge, which may cause burns or other injury.

 

CAUTION 

 

Installation, inspection, maintenance, repairs, disassembly, adjustment and valve 
opening/closing should be carried out only by trained maintenance personnel. 
1.  Before installation, be sure to remove all protective seals. 
2.  Before installing the product, blow out the inlet piping to remove any piping 

scraps, dirt and oil. Close the inlet valve after blowdown. 

3.  Install the product at the point on the piping where the separation of condensate 

will have the greatest effect on efficiency. For example, on a steam main or 
branch at the inlet of equipment requiring high-quality dry steam. 

4.  Install the product so the arrow on the product is pointing in the direction of flow. 
5.  The product should be inclined no more than 10° horizontally and front-to-back. 
6.  Install a separator outlet valve and separator outlet piping, and steam trap outlet 

fittings and steam trap outlet piping. 

7.  To facilitate inspection and maintenance, install a union at the steam trap outlet 

and ensure that there is sufficient space for maintenance. 

8.  Open the inlet valve and outlet valves and check to make sure that the product 

functions properly. 

If there is a problem, determ

ine the cause by using the “Troubleshooting” guide in 

this manual. 

 

Tolerance Angle for Installation: 10° 

 

Make sure the product is installed 
with the raised TLV lettering on the 
body horizontal.

 

DO NOT use for toxic, flammable or otherwise hazardous fluids.

This product is a separator for steam that separates and discharges 

condensate from steam piping systems. Use only for steam and/or 

steam condensate. This product is for intended use only. Improper use 

may result in such hazards as damage to the product or malfunctions 

that may lead to serious accidents.

WARNING

Содержание DC3S-L

Страница 1: ...172 65286MA 03 DC3S L 6 October 2021 Cyclone Separator Trap for Steam DC3S L Copyright 2021 by TLV CO LTD All rights reserved...

Страница 2: ...instructions to be sure of using the separator trap properly For use on steam mains and branches the cyclone separator traps use centrifugal force to separate condensate from steam and feature a buil...

Страница 3: ...serious injury Indicates that there is a potential threat of death or serious injury Indicates that there is a possibility of injury or equipment product damage DO NOT use for toxic flammable or othe...

Страница 4: ...f fluids causing burns other injuries or damage Be sure to use only the recommended components when repairing the product and NEVER attempt to modify the product in any way Failure to observe these pr...

Страница 5: ...DESIGN CONDITIONS NOT OPERATING CONDITIONS Valve No is displayed for products with options This item is omitted from the nameplate when there are no options Configuration DO NOT use for toxic flammabl...

Страница 6: ...piping scraps dirt and oil Close the inlet valve after blowdown 3 Install the product at the point on the piping where the separation of condensate will have the greatest effect on efficiency For exa...

Страница 7: ...al pressure If there is insufficient flow or differential pressure is too large disassemble and check for clogging of the screen If the product should fail it may cause damage to piping and equipment...

Страница 8: ...ing the Trap Cover Part During Disassembly During Reassembly Trap Cover Bolt Remove with a socket wrench Consult the table of tightening torques and tighten to the proper torque Trap Cover Remove the...

Страница 9: ...groove in the separator body Screen Remove being careful not to bend Place on top of the separator being careful not to bend Wave Spring Remove with the separator Insert into the groove in the separat...

Страница 10: ...Exploded View Body Screen Separator Body Gasket Wave Spring Guide Pin Separator Body Body Bolt Float Cover Bolt Spring Washer Float Cover Float Trap Valve Seat Valve Seat Gasket Trap Cover Gasket Tra...

Страница 11: ...ds the maximum specified pressure or there is insufficient pressure differential between the trap inlet and outlet Compare specifications and actual operating conditions Steam is discharged or leaks f...

Страница 12: ...yond the control of TLV TII or TLV group companies or 6 improper storage maintenance or repair or 7 operation of the Products not in accordance with instructions issued with the Products or with accep...

Страница 13: ...ASSEMBLY AND SHIPMENT OF THE DEFECTIVE PRODUCT INJURY TO OTHER PROPERTY DAMAGE TO BUYER S OR THE FIRST END USER S PRODUCT DAMAGE TO BUYER S OR THE FIRST END USER S PROCESSES LOSS OF USE OR OTHER COMME...

Страница 14: ...d Nunawading Victoria 3131 Australia Tel Fax 61 0 3 9873 5610 61 0 3 9873 5010 In East Asia 36 Kaki Bukit Place 02 01 02 Singapore 416214 Tel Fax 65 6747 4600 65 6742 0345 Room 5406 No 103 Cao Bao Roa...