TLV DC3S-L Скачать руководство пользователя страница 2

 

172-65286MA-03  (DC3S-L)    6  Oct  2021

 

Contents 

 
Introduction ....................................................................... 1

 

Safety Considerations ....................................................... 2

 

Specifications .................................................................... 4

 

Configuration ..................................................................... 4

 

Installation ......................................................................... 5

 

Maintenance ...................................................................... 6

 

Disassembly/Reassembly ................................................. 7

 

Troubleshooting .............................................................. 10

 

TLV EXPRESS LIMITED WARRANTY ............................. 11

 

Service ............................................................................. 13

 

 
 
 
 

Introduction 

Thank you for purchasing the TLV cyclone separator trap for steam. 

This product has been thoroughly inspected before being shipped from the 
factory. When the separator trap is delivered, before doing anything else, 
check the specifications and external appearance to make sure nothing is out 
of the ordinary. Also be sure to read this manual carefully before use and 
follow the instructions to be sure of using the separator trap properly. 

For use on steam mains and branches, the cyclone separator traps use 
centrifugal force to separate condensate from steam, and feature a built-in 
free float steam trap for the automatic discharge of the collected condensate.     

The combination of separator and built-in trap makes this product suitable for 
use in locations where a separator would be installed together with a trap. 

If detailed instructions for special order specifications or options not contained 
in this manual are required, please contact TLV for full details. 

This instruction manual is for the models listed on the front cover. It is needed 
not only for installation but for subsequent maintenance, 
disassembly/reassembly and troubleshooting. Please keep it in a safe place 
for future reference. 

Содержание DC3S-L

Страница 1: ...172 65286MA 03 DC3S L 6 October 2021 Cyclone Separator Trap for Steam DC3S L Copyright 2021 by TLV CO LTD All rights reserved...

Страница 2: ...instructions to be sure of using the separator trap properly For use on steam mains and branches the cyclone separator traps use centrifugal force to separate condensate from steam and feature a buil...

Страница 3: ...serious injury Indicates that there is a potential threat of death or serious injury Indicates that there is a possibility of injury or equipment product damage DO NOT use for toxic flammable or othe...

Страница 4: ...f fluids causing burns other injuries or damage Be sure to use only the recommended components when repairing the product and NEVER attempt to modify the product in any way Failure to observe these pr...

Страница 5: ...DESIGN CONDITIONS NOT OPERATING CONDITIONS Valve No is displayed for products with options This item is omitted from the nameplate when there are no options Configuration DO NOT use for toxic flammabl...

Страница 6: ...piping scraps dirt and oil Close the inlet valve after blowdown 3 Install the product at the point on the piping where the separation of condensate will have the greatest effect on efficiency For exa...

Страница 7: ...al pressure If there is insufficient flow or differential pressure is too large disassemble and check for clogging of the screen If the product should fail it may cause damage to piping and equipment...

Страница 8: ...ing the Trap Cover Part During Disassembly During Reassembly Trap Cover Bolt Remove with a socket wrench Consult the table of tightening torques and tighten to the proper torque Trap Cover Remove the...

Страница 9: ...groove in the separator body Screen Remove being careful not to bend Place on top of the separator being careful not to bend Wave Spring Remove with the separator Insert into the groove in the separat...

Страница 10: ...Exploded View Body Screen Separator Body Gasket Wave Spring Guide Pin Separator Body Body Bolt Float Cover Bolt Spring Washer Float Cover Float Trap Valve Seat Valve Seat Gasket Trap Cover Gasket Tra...

Страница 11: ...ds the maximum specified pressure or there is insufficient pressure differential between the trap inlet and outlet Compare specifications and actual operating conditions Steam is discharged or leaks f...

Страница 12: ...yond the control of TLV TII or TLV group companies or 6 improper storage maintenance or repair or 7 operation of the Products not in accordance with instructions issued with the Products or with accep...

Страница 13: ...ASSEMBLY AND SHIPMENT OF THE DEFECTIVE PRODUCT INJURY TO OTHER PROPERTY DAMAGE TO BUYER S OR THE FIRST END USER S PRODUCT DAMAGE TO BUYER S OR THE FIRST END USER S PROCESSES LOSS OF USE OR OTHER COMME...

Страница 14: ...d Nunawading Victoria 3131 Australia Tel Fax 61 0 3 9873 5610 61 0 3 9873 5010 In East Asia 36 Kaki Bukit Place 02 01 02 Singapore 416214 Tel Fax 65 6747 4600 65 6742 0345 Room 5406 No 103 Cao Bao Roa...

Отзывы: