Do not place any vehicle on the lift at this time. Read the operation instructions(pg 12-
14) and cycle the lift up and down several times to ensure safety latches click together
and all air is removed from the system. Ensure all hydraulic fittings are tight and not
leaking. To lower the lift, the safety latch releases must be manually released. Latches
will automatically reset once the lift ascends approximately 17” from base. If latches
click out of sync, tighten the cable on the one that clicks first.
WARNING: DO NOT PERFORM ANY MAINTENANCE OR INSTALLATION
OF ANY COMPONENTS WITHOUT FIRST ENSURING THAT ELECTRICAL POWER
HAS BEEN DISCONNECTED AT THE SOURCE OR PANEL AND CANNOT BE
REENERGIZED UNTIL ALL MAINTENANCE AND/OR INSTALLATION PROCEDURES
ARE COMPLETED.
DANGER: DO NOT RUN POWER UNIT WITHOUT FLUID. DAMAGE TO PUMP
CAN OCCUR. THE POWER UNIT MUST BE KEPT DRY. DAMAGE TO POWER UNIT
CAUSED BY WATER OR OTHER LIQUIDS SUCH AS DETERGENTS, ACID ETC., IS
NOT COVERED UNDER WARRANTY.
WARNING:
The wiring must comply with local code. Have a certified licensed
electrician make the electrical hook-up to the power unit. Protect each circuit with time
delay fuse or circuit breaker 208v.230v single Phase. 60Hz 30 Amp.
Содержание HD2P-9000AF
Страница 24: ...20 FIG 1 9000AF 110 3 8 134 5 8 111 1 4 112 MAX 72 3 4 MIN 4 5 8 6 7 8 11 DIAGRAMS FIG 1 3...
Страница 25: ...21 FIG 2 9000AF 134 5 8 R 34 72 R 28 54 R 40 75 R 52 44 17 91...
Страница 26: ...22 FIG 3 9000AF Bottom Cable Sheave Top Cable Sheave Equalizing Cable 2 Carriage Locking Nuts 4...
Страница 27: ...23...
Страница 28: ...24 FIG 4 9000AF 12 PARTS FIG 4 5...
Страница 29: ...25 FIG 4B 9000AF...
Страница 34: ......