User Manual-VN1
Version C July 2020
11 of 23
11
Extension power cable
2.2.2
The actuator is supplied with a power cable (and/or signal cable). The cable(s) has/have flying leads in one
end for the user’s equipment connections. On the other end of the actuator, the cable is integrated into the
connector cover. The plug-in connector allows the user to replace the actuator without disconnecting the
flying leads.
It is important to use the extension power cable from the DC source with proper size to avoid a significant
voltage drop. The further away the DC source is, the larger the extension cable may need to be. Please refer
to the following table for the recommendation of the extension power cable size.
Extension cable type
Length of cable (L)
Min. allowed cross section (X)
Power extension cable L1 0 - 4 m
2.5 mm2 [AWG 16]
4 - 10 m
4 mm2 [AWG 12]
Signal extension cable L3 <10 m
AWG 20
>10 m
Check with your TiMOTION contact window
Power cable
L1
L3
12V DC
or
24V DC
Control Box
or
PLC
P1
P2
Signal cable