User Manual-MA2T
Version A August 2021
15 of 25
15
P3
Red
20
Vm+ output for connecting to
external control
Brown
20
Extend the actuator when short
circuit with P3 Red
Input current
≦
11mA
Gray
20
Retract the actuator when short
circuit with P3 Red
Black
20
Signal ground
The signal is potentially free and
independent from the motor power
circuit.
Both brown and orange signal wires are
normal close circuits when the actuator
is in the middle of the stroke.
The signal circuit is connected to the
motor power circuit, and the value Vm+
depends on actuator voltage.
Connect the limit switch signal wire to
the load <1A.
Orange
20
Connect to up limit switch normal
close pin (N.C.)
Yellow
20
Connect to low limit switch normal
close pin (N.C.)
White
20
CAN High, Hall signal output_S1,
Hall-POT signal output
For CAN High/Low:
Input Voltage
= 5V
Embedded 120 Ohms resistor for
synchronized function.
For Hall and PWM signal output:
Output Current
≦
5 mA
For Hall-POT
Blue
20
CAN Low, Hall signal output_S2,
PWM signal output