11
word “Timken” shown on the end node case. For tracking purposes, the
customer should also keep track of the mounting location of each unit so
that this information can be entered into the software package.
End Node Power:
Located on the bottom of the end node is an ON/OFF
toggle switch that must be flipped for transmissions to
commence. Note that a red LED light on top of the end
node blinks after each transmission. The first
communication occurs upon power ON.
End Node Battery Replacement:
1. The StatusCheck software will give notification that an end node has a
low battery. After initial notification, there are still several weeks until
the end node will stop operating. Please use part number SCVT589001
when ordering a replacement battery.
2. Remove the end node from the machine.
3. Turn off the end node.
4. Take the unit to a clean environment and wipe off the exterior prior to
opening the cover.
5. Open the end node by loosening the four cross tip screws visible from
the bottom housing.
6. Remove the C-size battery and dispose of in accordance with local
procedures.
7. A 3.0 VDC lithium battery must be used. See Figure 10 for proper
orientation.
8. Replace the cover, making sure the housing gasket is properly seated
and that the light pipe (tube) is positioned over the square white LED
on the main electronics board.
Reinsert the screws and tighten to
1.13 Nm (10 in-lbs).
9. Power the end node on and verify
that the unit LED flashes at least
once.
10. Re-install the end node on
monitored machine.
Figure 10: StatusCheck End Node
Battery Orientation ————————
RF Network Overview:
The StatusCheck System uses radio frequencies (RF) to transmit the data
from the end nodes to the data collection computer. The network uses
OFF
I
ON