The six data collection intervals for the StatusCheck end node and the
approximate battery lives are depicted in the table below:
Interval Setting
Data Collection Interval
Approx. Battery Life
15 (Default Setting)
Every 15 seconds
4.5 Months
30
Every 30 seconds
9 Months
60
Every 60 seconds
1.5 Years
300
Every 5 minutes
3 Years
600
Every 10 minutes
4.5 Years
The data collection interval is adjusted using dip switches located on the
signal processing board inside the end node case. As shown in Figure 8,
the dip switches are located on the left side of the board and can be
switched on or off using a pencil tip or small screwdriver (the ON position
is up). These switches are adjusted according to the tables below to
obtain the desired data collection intervals.
Caution:
Turn the unit power OFF before adjusting the dip switches and
use a non-conductive tool to adjust. Do not place unnecessary stress on
the boards while moving the dip switches.
The 15-second interval setting is obtained by positioning the internal dip
switches as follows:
Switch
1
2
3
4
On
Off
I
X
I
X
I
X
I
X
The 30-second interval setting is obtained by positioning the internal dip
switches as follows:
Switch
1
2
3
4
On
X
Off
I I
X
I
X
I
X