Connection to electric mains
1. The convector is designed to be connected to 220V~, 50Hz single-
phase voltage mains with a grounding circuit.
2. Prior to connection make sure that parameters of electric mains
in the place of connection comply with parameters, indicated on the
identification plate with technical data of the unit.
3. t is necessary to follow active electrical safety precautions, connecting
the convector to electric mains.
4. An electric outlet must be properly grounded. The outlet must be
designed for rated current not less than 10A. Electric outlet and plug must
always stay dry to prevent current leakage. Regularly check if the electric
plug is tightly connected to the outlet. It must be done in the following
order: connect an electric plug into an outlet, after half hour operation turn
off the convector and disconnect the plug from the outlet, check if the
plug is heated by your hand. If the plug heated over 50°C then replace
the outlet by a new one to prevent damages, incidents, fire as a result of
bad electric contact. A specialist must do the job.Нословтому
Fig. 6
TEC.PF3 M…IN series convectors are equipped with a mechanical
thermostat.
TEC.PF3 LE…IN series convectors are equipped with a high-precision
electronic thermostat with a LED-display.
1. «Heating» indicator light
It is illuminated when the unit’s heating is on.
2. Thermostat handle
It is used to set the desired room temperature.
3. Two-button switch, with display
It is used to select the following heating power modes: I mode (low power),
II mode (medium power), III mode (high power).
Operation of TEC.PF3 M…IN series convector
1. Switch on the convector
Connect the convector to electric mains by plugging the power cord into
an electric outlet.
2. Select the heating power
2.1. Press button «1» to select the low heating power, at that the indicator
light of button «1» will be illuminated.
2.2. Press button «2» to select the medium heating power, at that the
indicator light of button «2» will be illuminated.
2.3. Press button «1» and «2» to select the high heating power, at that
indicator lights of both buttons will be illuminated.
Fig. 7
IMPORTANT!
The electric outlet must be rated for not less than 10A,
electric cable with a strand with cross section not less
than 3x1.5 mm
2
(for copper).
IMPORTANT!
Warning! It is forbidden to use convector on the floor
or any other horizontal surface without casters!
7. CONTROL OF THE CONVECTOR
1
2
4
TEC.PF3 M...IN series control panel (Fig. 7)
Содержание TEC.PF3 LE 2000 IN
Страница 11: ...www timberk com 11 imberk Timberk 220 50 1 2 3 4 5 6 1 2...
Страница 12: ...www timberk com 12 7 8 9 180 10 11 12 13 14 15 16 17 18 TEC PF3 LE IN 19 20 21 22 23 24 25 26 27 28...
Страница 14: ...www timberk com 14 1 2 3 4 5 4 2 5 20 1 1 2 1 3 2 4 1 5 1 6 1 6 5 1 2 3 1 4 5 2 3...
Страница 15: ...www timberk com 15 4 5 3 4 5 6 4 7 50 60 5 8 5 9 6 1 2 2 3 4 5 1 220 50 2 3 6...
Страница 21: ...www timberk com 21 Timberk Timberk www btpart ru www timberk com Timberk www btpart ru Timberk www btpart ru...
Страница 22: ...www timberk com 22 Timberk c 10...
Страница 24: ...www timberk com...