Connection to electric mains

1. The convector is designed to be connected to 220V~, 50Hz single-

phase voltage mains with a grounding circuit.
2. Prior to connection make sure that parameters of electric mains 

in the place of connection comply with parameters, indicated on the 

identification plate with technical data of the unit.
3. t is necessary to follow active electrical safety precautions, connecting 

the convector to electric mains.
4. An electric outlet must be properly grounded. The outlet must be 

designed for rated current not less than 10A. Electric outlet and plug must 

always stay dry to prevent current leakage. Regularly check if the electric 

plug is tightly connected to the outlet. It must be done in the following 

order: connect an electric plug into an outlet, after half hour operation turn 

off the convector and disconnect the plug from the outlet, check if the 

plug is heated by your hand. If the plug heated over 50°C then replace 

the outlet by a new one to prevent damages, incidents, fire as a result of 

bad electric contact. A specialist must do the job.Нословтому

Fig. 6

TEC.PF3 M…IN series convectors are equipped with a mechanical 

thermostat.
TEC.PF3 LE…IN series convectors are equipped with a high-precision 

electronic thermostat with a LED-display.

1. «Heating» indicator light

It is illuminated when the unit’s heating is on.

2. Thermostat handle

It is used to set the desired room temperature.

3. Two-button switch, with display

It is used to select the following heating power modes: I mode (low power), 

II mode (medium power), III mode (high power).

Operation of TEC.PF3 M…IN series convector

1. Switch on the convector

Connect the convector to electric mains by plugging the power cord into 

an electric outlet.

2. Select the heating power

2.1. Press button «1» to select the low heating power, at that the indicator 

light of button «1» will be illuminated.
2.2. Press button «2» to select the medium heating power, at that the 

indicator light of button «2» will be illuminated.
2.3. Press  button  «1» and «2» to select the high heating power, at that 

indicator lights of both buttons will be illuminated.

Fig. 7

IMPORTANT! 

The electric outlet must be rated for not less than 10A, 

electric cable with a strand with cross section not less 

than 3x1.5 mm

2

 (for copper).

IMPORTANT! 

Warning! It is forbidden to use convector on the floor 

or any other horizontal surface without casters!

7. CONTROL OF THE CONVECTOR

1

2

4

TEC.PF3 M...IN series control panel (Fig. 7)

Содержание TEC.PF3 LE 2000 IN

Страница 1: ...TEC PF3 M 1000 IN TEC PF3 M 1500 IN TEC PF3 M 2000 IN TEC PF3 LE 1000 IN TEC PF3 LE 1500 IN TEC PF3 LE 2000 IN Electric convector heater Outlook of devices aslo colour scores can be revised without an...

Страница 2: ...ting element cooled down prior to the unit is dismantled and packed for long term storage 5 When the unit is not operated for a long time store it factory packaged in a dry and cool place 6 DO NOT COV...

Страница 3: ...electric extenders However if necessary an extender may be used if its parameters comply with the unit s power and if it is not used by other power energy consumers 25 For normal operation of the unit...

Страница 4: ...ment and differ from each other by the unit s length at equal height and depth Standard overall height of all units is equal to 400 mm This pattern in forming overall dimensions allows the consumer to...

Страница 5: ...owels attach the mounting bracket and fasten adjusting screws thereby securing the bracket on the wall 7 Mount the convector on the bracket by connecting 4 slots on the back part of the convector with...

Страница 6: ...eries convectors are equipped with a mechanical thermostat TEC PF3 LE IN series convectors are equipped with a high precision electronic thermostat with a LED display 1 Heating indicator light It is i...

Страница 7: ...s connected to electric mains TEC PF3 EL IN series control panel Fig 8 14 3 LED display LED display can show temperature and timer settings 4 Comfort mode indicator It is illuminated when the convecto...

Страница 8: ...isplay The convector will automatically maintain temperature within the range 5 C to 7 C switching on and off heating from time to time 5 Set the convector switch off timer function 5 1 When the conve...

Страница 9: ...including materials with abrasive elements Prevent damaging the unit by sharp objects since scratches on a painted surface may cause rusting Rear surface of the convector must also be regularly clean...

Страница 10: ...dy 1 The heater heats poorly 1 The heating element is faulty 1 Contact the authorized service center of Timberk 2 Low voltage in the electric mains 2 Check voltage in the electric mains 2 The heater d...

Страница 11: ...www timberk com 11 imberk Timberk 220 50 1 2 3 4 5 6 1 2...

Страница 12: ...www timberk com 12 7 8 9 180 10 11 12 13 14 15 16 17 18 TEC PF3 LE IN 19 20 21 22 23 24 25 26 27 28...

Страница 13: ...50 500 1000 1500 6 8 4 4 595 400 69 TEC PF3 M 2000 IN 220 50 800 1200 2000 9 1 5 6 830 400 69 TEC PF3 LE 1000 IN 220 50 400 600 1000 4 5 3 6 460 400 69 TEC PF3 LE 1500 IN 220 50 500 1000 1500 6 8 4 4...

Страница 14: ...www timberk com 14 1 2 3 4 5 4 2 5 20 1 1 2 1 3 2 4 1 5 1 6 1 6 5 1 2 3 1 4 5 2 3...

Страница 15: ...www timberk com 15 4 5 3 4 5 6 4 7 50 60 5 8 5 9 6 1 2 2 3 4 5 1 220 50 2 3 6...

Страница 16: ...imberk com 16 4 10 2000 12 2500 50 10 3 1 5 2 TEC PF3 M IN TEC PF3 LE IN c LED TEC PF3 M IN 7 7 1 2 3 1 heating 2 3 1 2 3 TEC PF3 M IN 1 2 2 1 1 1 2 2 2 2 2 3 1 2 3 3 1 5 30 3 2 max heating heating 4...

Страница 17: ...www timberk com 17 5 comfort comfort 6 0 8 10 9 8 3 4 7 12 5 6 2 1 13 11 TEC P F3 LE IN 14 1 2 3 LED 4 5 6 7 8 AF 9 10 up 11 down 12 13 14 1 2 3 TEC PF3 LE IN 1 2 2 1 1 1 2 2 2 2...

Страница 18: ...www timberk com 18 2 3 1 2 3 3 1 5 30 1 3 2 24 17 3 3 LED 3 4 LED 3 5 LED 4 4 1 4 2 4 3 LED AF 5 7 5 5 1 LED 0 5 2 1 0 24 LED 5 3 3 5 4 LED 5 5 0 6 6 1 LED 0 6 2 1 0 24 LED 6 3 7 8 8 1 3 LED 3...

Страница 19: ...www timberk com 19 8 2 3 9 9 1 9 2 9 3 10 RESTART 11 3 TEC PF3 LE IN 5 10 2003 3 2 2 4 1294 03 2 n 3 n 3 Y N 400 n 400 0 4 Y 1 0 n 50000 n 50000 8...

Страница 20: ...www timberk com 20 9 TEC PF3 M 1000 IN TEC PF3 M 1500 IN TEC PF3 M 2000 IN TEC PF3 LE 1000 IN TEC PF3 LE 1500 IN TEC PF3 LE 2000 IN 10 9 10 Timberk 11 1 1 1 Timberk 2 2 2 1 1 2 2 3 3 4 4 Timberk...

Страница 21: ...www timberk com 21 Timberk Timberk www btpart ru www timberk com Timberk www btpart ru Timberk www btpart ru...

Страница 22: ...www timberk com 22 Timberk c 10...

Страница 23: ...www timberk com 23 www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com...

Страница 24: ...www timberk com...

Отзывы: