7

Fig. 8

10

9

8

3

4

7 12 5

6

2

1

13

11

3. Set temperature

3.1. Temperature can be set within the range +5 to +30°C.
3.2. Turn the thermostat handle clockwise to the stop to position “max”, at 

that if room temperature is below the set one, then the “heating” indicator 

light must be illuminated. When the room temperature reaches the desired 

level, turn the thermostat handle counterclockwise until the unit is switched 

off, the “heating” indicator light will go out. Now the thermostat will maintain 

the set temperature, switching on and off the convector from time to time.
During especially cold weather the convector may not be able to provide 

the required room heating. In this case set the thermostat to the level 

somewhat higher than the desired one.

4. «Antifreeze» mode

Turn the thermostat handle counterclockwise to position “min”. The 

thermostat will automatically switch on heating of the convector, if the room 

temperature goes below +5°C and the unit is connected to electric mains 

and the heating mode is on.

5. «Comfort» mode

«Comfort» mode, which can be selected by means of the thermostat 

handle, corresponds to the most comfortable room temperature.

1. Button «       »

It is used to switch on and off the convector.

2. Power indicator  «        »

It is illuminated when the unit is connected to electric mains.

TEC.PF3 EL...IN series control panel (Fig. 8)

14

3. LED-display

LED-display can show temperature and timer settings.

4. Comfort mode indicator «       »

It is illuminated when the convector is operating in the comfort mode.

5. Air ionizer indicator «       »

It is illuminated when the air ionizing function is activated.

6. Heating indicator  «        »

It is illuminated when the convector is operating in the heating mode.

7. Economy operation mode indicator «        »

It is illuminated when the convector is operating in the economy mode. 

8. Button «        »

It is used to select the following operation modes: comfort mode (indicator 

«     »), economy mode (indicator«     »), antifreeze mode (symbol «AF»).

9. Ionizer button «        »

It is used to turn on/off air ionizing.

10. Button «up» («        »)

It is used to increase the selected value.

11. Button “down” («       »)

It is used to decrease the selected value.

12. Timer indicator «        »

It is illuminated when the convector switch off timer function is activated.

13. Button  «        »

It is used to set temperature in the comfort mode (indicator «        »), in 

the economy mode (indicator «       »), as well as to set the timer (indicator 

«       »).

14. Two-button switch, with display

It is used to select the following heating power modes: 1 mode (low power), 

2 mode (medium power), 3 mode (high power).

Operation of TEC.PF3 LE…IN series convector
1. Switch on the convector

Connect the convector to electric mains by plugging the power cord into an 

electric outlet, at that a red power indicator «       » will be illuminated on the 

control panel and a sound signal will be given, then press button  «        ».

Содержание TEC.PF3 LE 2000 IN

Страница 1: ...TEC PF3 M 1000 IN TEC PF3 M 1500 IN TEC PF3 M 2000 IN TEC PF3 LE 1000 IN TEC PF3 LE 1500 IN TEC PF3 LE 2000 IN Electric convector heater Outlook of devices aslo colour scores can be revised without an...

Страница 2: ...ting element cooled down prior to the unit is dismantled and packed for long term storage 5 When the unit is not operated for a long time store it factory packaged in a dry and cool place 6 DO NOT COV...

Страница 3: ...electric extenders However if necessary an extender may be used if its parameters comply with the unit s power and if it is not used by other power energy consumers 25 For normal operation of the unit...

Страница 4: ...ment and differ from each other by the unit s length at equal height and depth Standard overall height of all units is equal to 400 mm This pattern in forming overall dimensions allows the consumer to...

Страница 5: ...owels attach the mounting bracket and fasten adjusting screws thereby securing the bracket on the wall 7 Mount the convector on the bracket by connecting 4 slots on the back part of the convector with...

Страница 6: ...eries convectors are equipped with a mechanical thermostat TEC PF3 LE IN series convectors are equipped with a high precision electronic thermostat with a LED display 1 Heating indicator light It is i...

Страница 7: ...s connected to electric mains TEC PF3 EL IN series control panel Fig 8 14 3 LED display LED display can show temperature and timer settings 4 Comfort mode indicator It is illuminated when the convecto...

Страница 8: ...isplay The convector will automatically maintain temperature within the range 5 C to 7 C switching on and off heating from time to time 5 Set the convector switch off timer function 5 1 When the conve...

Страница 9: ...including materials with abrasive elements Prevent damaging the unit by sharp objects since scratches on a painted surface may cause rusting Rear surface of the convector must also be regularly clean...

Страница 10: ...dy 1 The heater heats poorly 1 The heating element is faulty 1 Contact the authorized service center of Timberk 2 Low voltage in the electric mains 2 Check voltage in the electric mains 2 The heater d...

Страница 11: ...www timberk com 11 imberk Timberk 220 50 1 2 3 4 5 6 1 2...

Страница 12: ...www timberk com 12 7 8 9 180 10 11 12 13 14 15 16 17 18 TEC PF3 LE IN 19 20 21 22 23 24 25 26 27 28...

Страница 13: ...50 500 1000 1500 6 8 4 4 595 400 69 TEC PF3 M 2000 IN 220 50 800 1200 2000 9 1 5 6 830 400 69 TEC PF3 LE 1000 IN 220 50 400 600 1000 4 5 3 6 460 400 69 TEC PF3 LE 1500 IN 220 50 500 1000 1500 6 8 4 4...

Страница 14: ...www timberk com 14 1 2 3 4 5 4 2 5 20 1 1 2 1 3 2 4 1 5 1 6 1 6 5 1 2 3 1 4 5 2 3...

Страница 15: ...www timberk com 15 4 5 3 4 5 6 4 7 50 60 5 8 5 9 6 1 2 2 3 4 5 1 220 50 2 3 6...

Страница 16: ...imberk com 16 4 10 2000 12 2500 50 10 3 1 5 2 TEC PF3 M IN TEC PF3 LE IN c LED TEC PF3 M IN 7 7 1 2 3 1 heating 2 3 1 2 3 TEC PF3 M IN 1 2 2 1 1 1 2 2 2 2 2 3 1 2 3 3 1 5 30 3 2 max heating heating 4...

Страница 17: ...www timberk com 17 5 comfort comfort 6 0 8 10 9 8 3 4 7 12 5 6 2 1 13 11 TEC P F3 LE IN 14 1 2 3 LED 4 5 6 7 8 AF 9 10 up 11 down 12 13 14 1 2 3 TEC PF3 LE IN 1 2 2 1 1 1 2 2 2 2...

Страница 18: ...www timberk com 18 2 3 1 2 3 3 1 5 30 1 3 2 24 17 3 3 LED 3 4 LED 3 5 LED 4 4 1 4 2 4 3 LED AF 5 7 5 5 1 LED 0 5 2 1 0 24 LED 5 3 3 5 4 LED 5 5 0 6 6 1 LED 0 6 2 1 0 24 LED 6 3 7 8 8 1 3 LED 3...

Страница 19: ...www timberk com 19 8 2 3 9 9 1 9 2 9 3 10 RESTART 11 3 TEC PF3 LE IN 5 10 2003 3 2 2 4 1294 03 2 n 3 n 3 Y N 400 n 400 0 4 Y 1 0 n 50000 n 50000 8...

Страница 20: ...www timberk com 20 9 TEC PF3 M 1000 IN TEC PF3 M 1500 IN TEC PF3 M 2000 IN TEC PF3 LE 1000 IN TEC PF3 LE 1500 IN TEC PF3 LE 2000 IN 10 9 10 Timberk 11 1 1 1 Timberk 2 2 2 1 1 2 2 3 3 4 4 Timberk...

Страница 21: ...www timberk com 21 Timberk Timberk www btpart ru www timberk com Timberk www btpart ru Timberk www btpart ru...

Страница 22: ...www timberk com 22 Timberk c 10...

Страница 23: ...www timberk com 23 www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com...

Страница 24: ...www timberk com...

Отзывы: