background image

www.timberk.com • electric convector heater

8

2. Select the heating power mode

2.1. Press button «1» to select the low heating power, at that the indicator 

light of button «1» will be illuminated.
2.2. Press button «2» to select the medium heating power, at that the 

indicator light of button «2» will be illuminated.
2.3.  Press button «1» and «2» to select the high heating power, at that 

indicator lights of both buttons will be illuminated.

3. Set temperature

3.1. Temperature can be set within the range +5 to +30°C, in increments 

of 1°C.
3.2. Factory setting of the comfort mode temperature is +24°C, factory 

setting of the economy mode temperature is +17°C.
3.3. To change the comfort mode temperature, press button «     » once, 

at that the comfort mode indicator «       » and value of the set temperature 

on LED-display will be blinking, then press button «        » or  «       » to set 

the desired temperature.
3.4. To change the economy mode temperature, press button «      » twice, 

at that the economy mode indicator «       » and value of the set temperature 

on LED-display will be blinking, then press button «        » or  «       » to set 

the desired temperature.
3.5. After the desired temperature is set, the last set value will be stored 

and LED-display will show the current temperature, at that if room 

temperature is less than the set one, then the heating indicator «       » 

must be illuminated. When room temperature reaches the desired level, 

the heating indicator «      » will go out. The convector will maintain the set 

temperature, switching on and off heating from time to time.

4. Select the operation mode

4.1. Press button «     » once to select the comfort operation mode, at that 

indicator «     »  will be illuminated on the control panel. In this mode the 

convector will automatically maintain the set comfort mode temperature, 

switching on and off heating from time to time.
4.2. Press button «      » twice to select the economy operation mode, at 

that indicator «    » will be illuminated on the control panel. In this mode the 

convector will automatically maintain the set economy mode temperature, 

switching on and off heating from time to time.
4.3. Press button «     » three times to select the antifreeze mode, at 

that symbol «AF» will be shown on the LED-display. The convector will 

automatically maintain temperature within the range +5°C to +7°C, 

switching on and off heating from time to time.

5. Set the convector switch off timer function

5.1. When the convector is operating press button «      » three times, at that 

indicator «       » will be blinking on the control panel, and LED-display will 

show blinking value [0.0] or the last set value of the timer.
5.2. Press button «       » or «      »to set the convector switch off time, in 

increments of 1 hour, from 0 to 24 hours. The LED-display will show the 

countdown of time left until the convector is switched off.
5.3. The set time value will be stored and in 3 seconds the system will 

automatically return to indicating the temperature value, at that indicator     

«      » will be illuminated on the control panel.
5.4. The convector will be switched off after the timer expires, indicators on 

the control panel and temperature indication on the LED-display will go out, 

at that red power indicator «      » will be illuminated.
5.5. Switching off the unit or setting the timer value [0.] will cancel the 

convector switch off timer function.

6. Set the convector switch on timer function

6.1. When the convector is switched off and only red power indicator
 «        » is be illuminated, press button «       » and «       » simultaneously, 

at that a sound signal will be given, indicator «       » will start blinking on the 

control panel, and sense [0.] Will blink on LED display .
6.2. Press button «     » or «     » to set the convector switch off time, in 

increments of 1 hour, from 0 to 24 hours. Setuped time value will be saved. 

The LED-display will show time left until the convector is switched on will 

be shown on the display and indicator «      » will be illuminated on the 

control panel.
6.3. The convector will be switched on to operate in the economy mode 

after the timer expires, and will maintain the set temperature.

7. Audio signal

An audio signal is given when the convector is switched on and off, as well 

as the buttons are pressed.

8. Lock

8.1. When the convector is operating, to lock the system simultaneously 

press and hold buttons «       » and «       » for 3 seconds, after that symbol 

«[   ]» will be shown on the LED-display. In 3 seconds temperature Value will 

be shown, at that buttons on the control panel will be locked, and symbol 

«[   ]» will be shown when they are pressed.
8.2. To unlock the system, press and hold buttons  «       » and «       » for 3 

seconds or switch off the convector.

Содержание TEC.PF3 LE 2000 IN

Страница 1: ...TEC PF3 M 1000 IN TEC PF3 M 1500 IN TEC PF3 M 2000 IN TEC PF3 LE 1000 IN TEC PF3 LE 1500 IN TEC PF3 LE 2000 IN Electric convector heater Outlook of devices aslo colour scores can be revised without an...

Страница 2: ...ting element cooled down prior to the unit is dismantled and packed for long term storage 5 When the unit is not operated for a long time store it factory packaged in a dry and cool place 6 DO NOT COV...

Страница 3: ...electric extenders However if necessary an extender may be used if its parameters comply with the unit s power and if it is not used by other power energy consumers 25 For normal operation of the unit...

Страница 4: ...ment and differ from each other by the unit s length at equal height and depth Standard overall height of all units is equal to 400 mm This pattern in forming overall dimensions allows the consumer to...

Страница 5: ...owels attach the mounting bracket and fasten adjusting screws thereby securing the bracket on the wall 7 Mount the convector on the bracket by connecting 4 slots on the back part of the convector with...

Страница 6: ...eries convectors are equipped with a mechanical thermostat TEC PF3 LE IN series convectors are equipped with a high precision electronic thermostat with a LED display 1 Heating indicator light It is i...

Страница 7: ...s connected to electric mains TEC PF3 EL IN series control panel Fig 8 14 3 LED display LED display can show temperature and timer settings 4 Comfort mode indicator It is illuminated when the convecto...

Страница 8: ...isplay The convector will automatically maintain temperature within the range 5 C to 7 C switching on and off heating from time to time 5 Set the convector switch off timer function 5 1 When the conve...

Страница 9: ...including materials with abrasive elements Prevent damaging the unit by sharp objects since scratches on a painted surface may cause rusting Rear surface of the convector must also be regularly clean...

Страница 10: ...dy 1 The heater heats poorly 1 The heating element is faulty 1 Contact the authorized service center of Timberk 2 Low voltage in the electric mains 2 Check voltage in the electric mains 2 The heater d...

Страница 11: ...www timberk com 11 imberk Timberk 220 50 1 2 3 4 5 6 1 2...

Страница 12: ...www timberk com 12 7 8 9 180 10 11 12 13 14 15 16 17 18 TEC PF3 LE IN 19 20 21 22 23 24 25 26 27 28...

Страница 13: ...50 500 1000 1500 6 8 4 4 595 400 69 TEC PF3 M 2000 IN 220 50 800 1200 2000 9 1 5 6 830 400 69 TEC PF3 LE 1000 IN 220 50 400 600 1000 4 5 3 6 460 400 69 TEC PF3 LE 1500 IN 220 50 500 1000 1500 6 8 4 4...

Страница 14: ...www timberk com 14 1 2 3 4 5 4 2 5 20 1 1 2 1 3 2 4 1 5 1 6 1 6 5 1 2 3 1 4 5 2 3...

Страница 15: ...www timberk com 15 4 5 3 4 5 6 4 7 50 60 5 8 5 9 6 1 2 2 3 4 5 1 220 50 2 3 6...

Страница 16: ...imberk com 16 4 10 2000 12 2500 50 10 3 1 5 2 TEC PF3 M IN TEC PF3 LE IN c LED TEC PF3 M IN 7 7 1 2 3 1 heating 2 3 1 2 3 TEC PF3 M IN 1 2 2 1 1 1 2 2 2 2 2 3 1 2 3 3 1 5 30 3 2 max heating heating 4...

Страница 17: ...www timberk com 17 5 comfort comfort 6 0 8 10 9 8 3 4 7 12 5 6 2 1 13 11 TEC P F3 LE IN 14 1 2 3 LED 4 5 6 7 8 AF 9 10 up 11 down 12 13 14 1 2 3 TEC PF3 LE IN 1 2 2 1 1 1 2 2 2 2...

Страница 18: ...www timberk com 18 2 3 1 2 3 3 1 5 30 1 3 2 24 17 3 3 LED 3 4 LED 3 5 LED 4 4 1 4 2 4 3 LED AF 5 7 5 5 1 LED 0 5 2 1 0 24 LED 5 3 3 5 4 LED 5 5 0 6 6 1 LED 0 6 2 1 0 24 LED 6 3 7 8 8 1 3 LED 3...

Страница 19: ...www timberk com 19 8 2 3 9 9 1 9 2 9 3 10 RESTART 11 3 TEC PF3 LE IN 5 10 2003 3 2 2 4 1294 03 2 n 3 n 3 Y N 400 n 400 0 4 Y 1 0 n 50000 n 50000 8...

Страница 20: ...www timberk com 20 9 TEC PF3 M 1000 IN TEC PF3 M 1500 IN TEC PF3 M 2000 IN TEC PF3 LE 1000 IN TEC PF3 LE 1500 IN TEC PF3 LE 2000 IN 10 9 10 Timberk 11 1 1 1 Timberk 2 2 2 1 1 2 2 3 3 4 4 Timberk...

Страница 21: ...www timberk com 21 Timberk Timberk www btpart ru www timberk com Timberk www btpart ru Timberk www btpart ru...

Страница 22: ...www timberk com 22 Timberk c 10...

Страница 23: ...www timberk com 23 www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com...

Страница 24: ...www timberk com...

Отзывы: