33
8.6. MENU 06
– Initial loading
When the all pellet is used, the dozer will be emptied also so that even when the pellet is
put into the warehouse, it will take some time for the feeder to be filled before the furnace
can start.
When the pellet is emptied,
ALARM NO FIRE
appears which is described in the ALARMS
section. After pouring the pellets into the storage, the following should be done: Press the
key 3 (set), after which the
text MENU 01 SET CLOCK
will be displayed. Then press the 5
key 5 times, followed by the text
MENU 06 LOAD INITIAL
(Image 32).
By pressing key 3 (set), enter the pellet feeder menu and the
text OFF MENU 06 P1 TO
LOAD
is displayed. Press 1. to fill the pellet dispenser. After 45 seconds, the first pellets
will fall into the burning pot.
Image 32
To stop loading press Key 4.
Note: Use this function only when the pellet storage is empty.
At the moment when it is evident that the pellet transporter has filled with the pellet
and the pellet has started to enter the burning pot, it is necessary to terminate the
pellet loading command and start the furnace.
You can only activate this function when the stove is off and the display says OFF.
8.7. MENU 07
– Information related to stove operation status
Information on the operation of the stove is useful because it can be monitored at any time
in which mode the stove is operating, the exhaust temperature, the fan speed, the time
remaining until the next operation, etc.
To enter the menu that monitors the operation of the stove, do the following: Press Key 3
(set), and the text MENU 01 SET CLOCK will be displayed. Then press the 5 key six times,
followed by the text MENU 07 STATE STOVE (Image 33).