TABLE 2.2
FREQUENCY SELECTION kHz
DIODE LOCATION
OPERATING
FREQUENCY
(kHz)
800 kHz
400 kHz
200 kHz
100 kHz
50 kHz
25 kHz
000 0 0 0 0 0 0
025 0 0 0 0 0 1
050 0 0 0 0 1 0
075 0 0 0 0 1 1
100 0 0 0 1 0 0
125 0 0 0 1 0 1
150 0 0 0 1 1 0
175 0 0 0 1 1 1
200 0 0 1 0 0 0
225 0 0 1 0 0 1
250 0 0 1 0 1 0
275 0 0 1 0 1 1
300 0 0 1 1 0 0
325 0 0 1 1 0 1
350 0 0 1 1 1 0
375 0 0 1 1 1 1
400 0 1 0 0 0 0
425 0 1 0 0 0 1
450 0 1 0 0 1 0
475 0 1 0 0 1 1
500 0 1 0 1 0 0
525 0 1 0 1 0 1
550 0 1 0 1 1 0
575 0 1 0 1 1 1
600 0 1 1 0 0 0
625 0 1 1 0 0 1
650 0 1 1 0 1 0
675 0 1 1 0 1 1
700 0 1 1 1 0 0
725 0 1 1 1 0 1
750 0 1 1 1 1 0
775 0 1 1 1 1 1
800 1 0 0 0 0 0
825 1 0 0 0 0 1
850 1 0 0 0 1 0
875 1 0 0 0 1 1
900 1 0 0 1 0 0
925 1 0 0 1 0 1
950 1 0 0 1 1 0
975 1 0 0 1 1 1
LEGEND:
0 = JUMPER BETWEEN CENTRE AND 0
1 = JUMPER BETWEEN CENTRE AND 1