1.3.2
AC and DC Operation
The units can be operated by external 120/220 VAC or external 28 VDC (13.7 VDC for Low
Power configurations).
1.
AC OPERATION
- During AC operation, the unit can charge and trickle charge external
batteries via the external connectors mounted on the rear panel of the unit. Refer to
Table 1.2 for details.
DC OPERATION
- The unit can be operated from an external DC supply within the range
of 21.6 Vdc to 30 Vdc for 15 watt and 25 watt configurations and within the range of 11.5
Vdc to 15.0 Vdc for Low Power configurations.
1.4 TECHNICAL
SUMMARY
A summary of electrical, operational, mechanical and physical characteristics of the Single
Channel Transmitters are provided in Table 1.1.