2008-10-20 Workshop Manual, Stiga Titan 7 Electrical System
5
7.2.2 The starter rotate but the motor does not start
There is fuel in the tank.
The fuel system is bleeded.
No other faults in the motor.
Is it 12 V during 1 sec after start
attempt at the front part of the
connector socket B5?
AND
Is it 12 V at the front part of the
connector socket B6 when
ignition is activated?
1. Replace the timer.
2. Replace the timer relay.
3. Replace the diode.
Replace/adjust the pedal
switch.
Clean the connector
socket A (pos A5).
Is it 12 V at the red cable terminal
H at the fuse box?
Perform actual measure
No
Yes
Yes
Yes
Are other electrical functions OK
when ignition is activated?
No
Yes
Is it 12 V during 1 sec. at the
white cable at the shut off valve?
AND
Is it 12 V at the red cable at the
shut off valve?
Replace the shut of valve.
No
No
No
Yes