![TIGA TITAN 20 B Скачать руководство пользователя страница 67](http://html.mh-extra.com/html/tiga/titan-20-b/titan-20-b_workshop-manual_1114793067.webp)
Edition
Manual
Chapter
Page
2008-10-23 Workshop Manual, Stiga Titan 4 Hydraulic system
38
4.7.4 Disassembly the PTO pump
Disassembly the PTO pump as follows:
1. Drain the hydraulic oil. See above.
2. Disconnet the hydraulic hoses from the
pump.
3. Dismantle the pump together with its carrier
plate/pulley. See “5.4 Hydraulic pumps belts,
26H, 26HS” in section 5.
Note the stabilisation spring. It shall also be
unhooked.
4. Take out the pump from the machine and set
up the pulley in a vise.
5. Unscrew the pulley nut and remove the pulley
from the shaft. If neccesary, use a puller. The
shaft fitting is conical.