2008-10-23 Workshop Manual, Stiga Titan 4 Hydraulic system
27
Location of actuator and hydraulic outputs at the machine
Description of components
1. PTO valve
The PTO valve is an integrated unit, containing all neccesary features for the implement
driving.
2. Electrical solenoid, 3. Slide
These parts are mechanic connected. The solenoid is affected of the switch PTO1.
4. Pressure limiting valve, 125 bar.
The pressure limiting valve secure that the pressure in the feeding line never can exceed
125 bar, i.e. if the rotating parts are blocked.
6. Brake valve
The brake valve minimizes the stop time for the implement.
7. Cooler
As the motor is started, the PTO oil passes through the cooler. Since the same oil is used
for the driving, the cooler keeps the hydraulic oil on a suitable level.
8. Leak oil line
The leak oil line transports all leak oil from the implement hydraulic motor back to the tank
via the collector block.
P. Hydraulic pump
The hydraulic pump is direct connected to the motor and runs always when the motor runs.
5. Collector block
The collector block collects leak oil and return oil from all hydraulic components to transit
it back to the tank.
PTO
PTO1
7
P