background image

Symbols on the instrument

Attention! Observe user instructions!

EC conformity

Device for live working

This device has to be disposed of according to the 

applicable regulations and laws  

(for Europe: WEEE 2012/19/EU).  

Please contact [email protected] in regard to the 

return of old devices.

12

1

6

4

8

TT 3K

Art.-no. 89337

3

7

red 

-LED for Voltage

green LED for Test and 
Absence of voltage

Display (LCD)

Frequency / DC

Voltage value

6

5

360° LED indication red / green

2

1.  Test electrode
2.  Red limiting mark
3.  Locking for pull-out
4.  Type plate
5.  Limiting disc
6. Handgear
7.   Display part
8.  Contact magnet or 

contact clamp or 
universal clamp

Содержание MultiSafe TT 3

Страница 1: ...ANY Telefon 49 2333 75989 info tietzsch de www tietzsch de TT3_BA_10 2017 Bedienungsanleitung User Instructions MultiSafe TT 3 Teleskop Spannungspr fer Telescope Voltage Tester Via Acquanera 29 22100...

Страница 2: ...rden Bei Fragen zur Altger te R cknahme wenden Sie sich bitte an service tietzsch de 1 Pr felektrode 2 rote Grenzmarke 3 Arretierung f r Auszug 4 Typenschild 5 Begrenzungsscheibe 6 Handhabe 7 Anzeiget...

Страница 3: ...o er Abstand gehalten werden Der Kontaktmagnet die Kontaktklemme muss fest mit Erdpotential verbunden sein z B Fahrschiene Die Erdleitung darf dabei keine unter Spannung stehenden Anlagenteile kreuzen...

Страница 4: ...destens unmittelbar vor und nach M glichkeit auch nach dem Gebrauch auf einwandfreie Funktion berpr ft werden Schritt 1 Test der Anzeige F r den Eigentest muss das Ger t ausgeschaltet sein Dr cken Sie...

Страница 5: ...tung Bei Spannungen ber 3 kV AC DC erscheint OL ohne Zahlenwert und ein akustisches Signal In diesem Fall muss die Pr fung sofort abgebrochen werden Hinweis Auch bei abgeschalteten geerdeten Fahrleitu...

Страница 6: ...chselt werden Das Ger t arbeitet mit 6 x AA Batterien nach IEC LR6 Alkali Mangan oder IEC FR6 Lithium Wir empfehlen die Verwendung von FR6 Batterien um eine lange Einsatzdauer zu erreichen 5 2 Batteri...

Страница 7: ...n 6 Jahre nicht berschreiten Je nach Einsatzbedingungen und H ufigkeit der Benutzung kann eine fr here Pr fung vom Anwender festgelegt werden Die Seriennummer mit Herstelldatum WWJJNN Woche Jahr Numme...

Страница 8: ...en Aussenraum Anlagen Anzeige Gruppe I und III Betriebstemperatur 15 C 55 Energiequelle 6 x AA 1 5 V nach IEC LR6 Alkali Mangan oder FR6 Lithium Eisensulfid Schutzart IP 65 Ger t bei Niederschlag verw...

Страница 9: ...9...

Страница 10: ......

Страница 11: ...dolph Tietzsch GmbH Co KG Willringhauser Stra e 18 58256 Ennepetal GERMANY Telefon 49 2333 75989 info tietzsch de www tietzsch de TT3_BA_10 2017 User Instructions MultiSafe TT 3 Telescope Voltage Test...

Страница 12: ...lease contact service tietzsch de in regard to the return of old devices 12 1 6 4 8 TT 3K Art no 89337 3 7 red LED for Voltage green LED for Test and Absence of voltage Display LCD Frequency DC Voltag...

Страница 13: ...tact clamp contact magnet has to be securely attached to the ground potential e g rail The grounding line must not cross live plant components The maximum on time of the MultiSafe TT 3 is 15 minutes O...

Страница 14: ...1 voltage testers must be checked if they function correctly briefly before and whenever possible after the use for determining absence of voltage Step 1 Test of the display The device must be switch...

Страница 15: ...n acoustic signal accurs In this case the test must be canceled immediately Note Also on grounded overhead lines interference voltages up to 300 V can be displayed The voltage tester is equipped with...

Страница 16: ...measurements can be performed and the battery has to be replaced immediately The device requires 6 x AA batteriess in accordance with IEC LR6 Alkaline or IEC FR6 Lithium We recommend to achieve the us...

Страница 17: ...n conditions and frequency a previous inspection may be recommendable The serial number with the date of manufacturing WWYYNN Week Year Number is imprinted inside the battery compartment of the displa...