Use these instructions as part of a training program as required by OSHA and any applicable state agency. The
user must understand how to safely use the Universal Guardrails and all safety equipment used in combination
with the Universal Guardrails.
A competent person who is highly trained and experienced, assigned by the employer, must be responsible for
all elements of a fall safety program, including the regulation, management, and application as it relates to the use
of the Universal Guardrails and related system.
Safety Information
Serious injury, bodily harm or death may result if there is a failure to understand and comply with safety
regulations. These instructions are not all-inclusive and are for reference only and not intended to replace a
competent person, knowledge or judgment of Federal and State Standards. New OSHA Rule in affect:
Walking-Working Surfaces, 1910.28, please consult this as well as all local, State and Federal OSHA rules
Workplace conditions including, but not limited to weather conditions, corrosive chemicals, potential electrical
hazards, sharp objects/surface, and slope of the surface must be evaluated by a competent person before equipment
is selected and installed and before work begins. Do Not misuse equipment. Do Not alter equipment. Unprotected
leading edges and sides that are 6 feet or more above the next lowest level require the use of these guardrails,
safety nets or personal fall protection devices. Never lean or climb on a Roof Zone Guardrail.
Inspection of the Universal Guardrail must take place routinely at intervals not to exceed 6 months. A competent
person other than the end user must be responsible for the inspection of the Universal Guardrail System. All
inspection must be recorded by a competent person who must sign their initials and date (month/year) in the
appropriate box on the inspection grid decal for the month and year the inspection was conducted.
Prior to installation/set-up of the Universal Guardrail System, a competent person must develop a system
layout plan.
1. Evaluate the roof surface to confirm that the Guardrail System will not be installed on top of gravel or slippery surfaces.
2. Measure the work surface area to be protected and space the Zip base plate accordingly (10 ft. centers for long
runs, 7-1/2’ and or 5 ft. centers where required).
3. All Zip Base plates must be located a minimum distance of 18 in. from a “no curb”/parapet leading edge, or
opening. If the work location has a curb or parapet edge, the Zip Base can be placed perpendicular against the
rise of the structure.
4. Always be aware of all electrical hazards (ELECTRICITY KILLS). A minimum safe distance of 10 ft. away from
power lines and other electrical hazards must be maintained at all times.
5. Zip base plates must be oriented correctly with the Universal Guardrails installed perpendicular. Toe boards are
installed parallel to the guardrails. Safety clips pins must be inserted through all zip base plates and guardrails.