5.Keep all the inflammable volatile materials well away
from operation area.
6.Be sure to understand the information of the battery
to be charged or discharged accurately. If the program is
set up incorrectly the battery can severely be damaged.
Especially Lithium battery can cause a fire or an
explosion by over-charging.
NiCd/NiMH voltage level: 1.2V/cell
allowable fast charge current: 1C—2C
depends on the performance of cell
discharge voltage cut off level: 0.85V/
cell(NiCd), 1.0V/cell(NiMH)
Lilo
voltage level: 3.6V/cell
max. charge voltage: 4.1V/cell
allowable fast charge current : 1C or less
min. discharge voltage cut off level: 2.5V/
cell or higher
LiPo voltage level: 3.7V/cell
max. charge voltage: 4.2V/cell
allowable fast charge current : 1C or less
min. discharge voltage cut off level: 3.0V/
cell or higher
LiFe voltage level: 3.3V/cell
max. charge voltage: 3.6V/cell
allowable fast charge current : 4C or less
(e.g.A123M1)
min. discharge voltage cut off level: 2.0V/
cell or higher
Pb voltage level: 2.0V/cell
(Lead-acid) max. charge voltage: 2.4V/cell
allowable fast charge current : 0.4C or
Содержание 75P-T6-Multi-Charger