Discharging Pb battery
Set discharge current
o n t h e l e f t a n d f i n a l
voltage on the right. The
discharge current ranges
from 0.1 to 1.0A.
To start the process,
press
Start/Enter
key
for more than 3 seconds.
The screen displays
t h e c u r r e n t s t a t e o f
discharge. You can alter
the discharge current by
pressing
Start/Enter
key during the process.
Once you change the
current value, store it by
pressing
Start/Enter
button again.
To stop discharging press
Batt type/Stop
key
once. The audible sound indicates you at the end of
process.
Save Data program
It has a data storage and load program for your
convenience. This feature can store up to 5 battery data
by number that represent the individual specification
of batteries you are using. They can be called back for
the process of charging or discharging without setting
up the program again. To set up the parameter value in
Pb DISCHARGE
1.0A 12.0V(6P)
Display
- +
DEC INC
Display
- +
DEC INC
Batt type
Stop
Start
Enter '>3 seconds'
Pb-6 0.4A 12.59V
DSC 022:43 00682
Display
Display
battery
type
elapsed
time
discharge
current
battery
voltage
discharged
capacity