Remote configuration of the transceiver via poll VMS connection for multiple
ocean regions
Page 5-16
9-Nov-00
connection is modified to contain all (LES id, DNID) pairs included
in the poll.
1 0 0 0 0 0 0 0
Command ( 8 bit)
Sequence Number (8 bit)
Spare (16 bit)
Result code = 1
(16 bit)
Checksum (8 bit)
Spare (8 bit)
Connection no. (8 bit)
CN = connection no.
Table 11 Positive Open Connection acknowledgement
The value of the checksum field is adjusted so a modulus 256
sum from and including the result code field is zero.
For all other Result codes the acknowledge report of Open Co n-
nection will be
1 0 0 0 0 0 0 0
Command ( 8 bit)
Sequence Number (8 bit)
Spare (16 bit)
Result code
(16 bit)
Spare (8 bit)
Table 12 Negative Open Connection acknowledgement