![Thrane&Thrane TT-3020C Скачать руководство пользователя страница 71](http://html.mh-extra.com/html/thraneandthrane/tt-3020c/tt-3020c_configuration-manual_1111406071.webp)
VMS Configuration
Remote configuration of the transceiver via poll
9-Nov-00
Page 5-1
5
Remote configuration of
the transceiver via poll
5.1
VMS Configuration
The following poll to sub-address 1 is defined by T&T:
Poll command
number
Command
n a m e
Meaning
6CH (108)
T&T Remote
configuration
This poll is used to configure the
transceiver remotely
Table 7 T&T Remote Configuration
The Inmarsat defined individual poll format is:
[Individual] ::= [MES ID][LESID][Subadr][DNID][Resp][Spare]
[Poll Ack][Command Type][Seqno][Datapart]
The individual T&T remote configuration poll has the following for-
mat:
Poll Ack (1 bit)
If this bit is set the transceiver will send a acknowledgement Data
Report acknowl edging the receipt of the Poll
Command Type (7 bit)
Value 6CH
Datapart
[
Data Part
] ::= [Zero field][Command array]