HA0409T Rev B Aug 2021
BBD30x Series Brushless DC Servo Controllers
Page 30
5.4 Moving to an Absolute Position
Absolute moves are measured in real world units (e.g. millimetres), relative to the
Home position.
1) Click the position display.
Fig. 5.3 Absolute Position Popup Window
2) Enter 3.0 into the pop up window
3) Click ‘OK’. Notice that the position display counts up to 3.000 to indicate a move
to the absolute position 3.00mm.
5.5 Stopping the Stage
The drive channel is enabled and disabled by clicking the ‘Enable’ button on the GUI
panel or the front panel of the unit. The green indicator is lit when the drive channel is
enabled. Disabling the channel removes the drive power and allows the stage/
actuator to be positioned manually.
During operation, the stage can be stopped at any time by clicking the ‘Stop’ button
on the GUI panel. Using this button does not remove power to the drive channel.