Turn ON the pilot and main burners and check the flame for any abnormalities.
18.
Adjust the burner’s air shutter, as necessary, to eliminate yellow flame and lifting of flames,
and other burner flame abnormalities.
19.
Refit the pilot covers, radiants, cast grates, front panel cover, and knobs.
21.
Before leaving the premises, ensure to check the functions of the following:
a.
Pilot burner ignition
b.
Pilot burner flame. It should stay lit.
c.
Main burners, “HIGH” flame and “LOW” flame.
d.
Check for gas leaks on the connections.
e.
Check the manifold pressure, ensure that it corresponds to the appropriate manifold
pressure for the gas type used.
CAUTION!
To avoid property damage, personal injury or death, all gas joints and connections
disturbed during servicing or gas conversion must be check for gas leaks. Check with a
soap and water solution (bubble test) or any gas leak detecting solution. Do not use
naked flame to check for gas leaks.
20.
After converting the unit, ensure to post the new rating label and gas conversion label with
the appropriate gas type used. Fill-up the Gas Conversion Label and attach it
to the unit
beside the new rating label.