26
f.
For the front burners, slacken the main pipe assembly connection to the safety gas valve.
Then, turn the main pipe assembly towards you for easy access to the main burner
injector.
g.
Remove and replace the main burner injector using 13mm spanner. Ensure to install the
correct main burner injector. Refer to the Gas Specification Table on page 5 of this manual
for the corresponding Main Burner Injector size for each specific gas type that the unit
will operate on.
h.
Reinstall the Main Pipe Assembly and tighten.
2.
Replace the Pilot Injectors (Hobs):
a.
Disconnect the pilot pipe assembly from the pilot injector. Slacken the nut of the pilot
pipe to allow for easy removal. Use 10mm spanner
b.
Remove and replace the Pilot Injector/FDS Injector from the pilot assembly. Use 10mm
spanner. Ensure to install the correct Pilot Injector. Refer to the Gas Specification Table
on page 5 of this manual for the corresponding Pilot Injector size for the specific gas type
that the unit will operate on.
c.
Reconnect the pilot pipe assembly to the pilot injector.
Pilot Pipe Assembly
Pilot Injector/
FDS Injector
Slacken the Main Pipe Assembly
connection to Safety Gas Valve
Pilot Injector/
FDS Injector
Main Burner Injector