The use of cabinets for storage above the appliance may result in a potential burn
hazard. Combustible items may ignite; metallic items may become hot and cause
burns. If a cabinet storage is to be provided, the risk can be reduced by installing a
range hood that projects horizontally a minimum of 5" (12.7cm) beyond the bottom
of the cabinets.
Dimensions and Clearances
The range may be installed flush to the rear wall. You may install a non-combustible
material on the rear wall above the range and up the vent hood. It is not necessary
to install non-combustible materials behind the range below the counter top height.
The minimum distance from the side of the range above the counter top to
combustible sidewalls must be at least 10 inches.
The appliance shall not be used for space heating. This information is
based on safety considerations. All openings in the wall behind the
appliance and in the floor under the appliance shall be sealed.