MEC 310 GENSET CONTROLLER
PM075 REV 2 09/08/20
Page 108
THOMSON TECHNOLOGY
6350 D+ input
No.
Setting
Min. setting
Max. setting
Factory
setting
6351
D+ input (P3)
Timer
0.0 s
100.0 s
10.0 s
6352
D+ input
Relay output A
R0 (none)
R26 (relay 26)
R0 (none)
6353
D+ input
Enable
OFF
ON
OFF
6354
D+ input
NO/NC
NO
NC
NO
6360 GB on water temp.
No.
Setting
Min. setting
Max. setting
Factory
setting
6361
GB on water temp.
Set point
0 C/F
100 C/F
40 C/F
6362
GB on water temp.
Enable
OFF
ON
OFF
6550 Fuel pump logic
No.
Setting
Min. setting
Max. setting
Factory
setting
6551
Fuel pump logic (P3) Set point 1
0%
100%
20%
6552
Fuel pump logic (P3) Set point 2
0%
100%
90%
6553
Fuel pump logic (P3) Timer
0.1 s
300.0 s
60.0 s
6554
Fuel pump logic
Enable
OFF
ON
OFF
6560 Cool-down timeout
No.
Setting
Min. setting
Max. setting
Factory
setting
6561
Cool-down timeout
Timer
0.0 s
9999.0 s
900.0 s
6562
Cool-down timeout
Relay output A
R0 (none)
R26 (relay 26)
R0 (none)
6563
Cool-down timeout
Relay output B
R0 (none)
R26 (relay 26)
R0 (none)
6570 Oil press. run detection
No.
Setting
Min. setting
Max. setting
Factory
setting
6571
Oil press. run detection
Set point
0 bar/PSI
150 bar/PSI
1 bar/PSI
6572
Oil press. run detection
Enable
OFF
ON
OFF
If the D+ input is selected to be ON, this will be used as a running feedback. The
D+ output from the charge generator must be connected to the input terminal
configured to this function. The terminal 9 (common for terminals 10-15) must
be connected to +, otherwise the D+ input does not work.
Parameter 6570 Oil pres. run detection makes it possible to use the oil pressure
as a running feedback.
10980 Config. input 1 must be set to VDO to activate the fuel pump logic.
A relay must be configured to fuel pump in output settings.