1.
Overview
4-3
4. TSC Functions
TSC
1-1
Type of function mode
TSC have 6 modes for different purposes and objectives.
The 6 modes have different number of positions, implemented functions, and
operation methods.
You can change the mode in the parameter No.36 (Function mode).
While program of each STEP in each mode is configured by the setup tool
D-STEP (the execution from outside will be performed by input/output signals).
For
more information, see the separate setup tool D-STEP Instruction Manual.
Function mode
Overview
Number of
steps
Pressing
operation
Multi-point positioning type
0: Position 64 type
Multi-point positioning operation with 64
points
With area output, with P area output
64
○
1: External unit input instruction
type
Multi-point positioning operation with 64
points
External instruction mode by I/O
Without area output, with P area output
64
-
2: Position 256 type
Multi-point positioning operation with
256 points
Without area output, with P area output
256
○
3: Position 512 type
Multi-point positioning operation with
512 points
Without area output, without P area
output
512
○
Electr
omagnetic
valve type
4: Solenoid mode 1 type
Multi-point positioning operation with 7
points
Direct move command input
With area output, with P area output
7
○
5: Solenoid mode 2 type
Multi-point positioning operation with 3
points
Direct move command input
Position sensor auto-switch output
With area output, with P area output
3
-
1-2
Selection by intended use
Intended use
Mode: 0
Position
64 type
Mode: 1
External
input
instruction
type
Mode: 2
Position
256 type
Mode: 3
Position
512 type
Mode: 4
Solenoid
mode 1
Mode: 5
Solenoid
mode 2
Move and instruction from I/O
-
○
-
-
-
-
Brake release from I/O
○
-
○
○
○
○
Pressing operation
○
-
○
○
○
-
Torque determination
○
-
○
○
○
-
Area output
○
-
-
-
○
○
P area output
○
○
○
-
○
○
Signal output during operation
○
○
-
-
-
-