![ThingMagic Astra-EX Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/thingmagic/astra-ex/astra-ex_user-manual_1106987062.webp)
Using Safe Mode
M6 and Astra-EX User Guide
62
Command line interface (through console port or telnet/ssh):
1.
Connect to the Readers serial port
(See
Connecting to the USB Console Port
.)
Enter the following to log into the console
Default UserID:
root
Password:
secure
2.
Type the command:
touch /tm/etc/safe-boot
3.
Click the Enter button.
4.
Type the command:
reboot
5.
Click the Enter button.
Reader reboots.
In both methods the M6 and Astra-EX will now boot into Safe Mode and you can connect
to it using the steps defined in
Connecting Your PC to the Reader
.