Using GPIO
M6 and Astra-EX User Guide
41
Note
For non-isolated applications connect grounds together (pin6 and 7) and V-GPO to
M6 and Astra-EX+5V (pins 1 and 5). With this configuration the reader provides the
+5V supply and can sink up to 200mA, total.
Connector Pinout
The following are the pin-outs of the 15-pin connector:
Figure 13:
DE15 GPIO Pinout
1.
M6 and Astra-EX+5V
- non-isolated power from M6 and Astra-EX
2.
N/A
3.
N/A
4.
User Output 2
(
GPIO_1
)
5.
V-GPO
- Isolated source power for outputs
6.
ISO-GND
- Isolated ground for outputs
7.
M6 and Astra-EX Ground
- non-isolated ground
8.
User Output 1
(
GPIO_0
)
9.
User Output 2
(
GPIO_1
)
10.
User Output 3
(
GPIO_2
)
11.
User Output 4
(
GPIO_5
)
12.
User Input 1
(
GPIO_3
)
13.
User Input 2
(
GPIO_4
)
14.
User Input 3
(
GPIO_6
)
15.
User Input 4
(
GPIO_7
)
Note:
The values in parentheses indicate the enumeration used by the MercuryAPI for each GPIO line.
Содержание Astra-EX
Страница 1: ...1 Mercury6 M6 and Astra EX User Guide For firmware version 4 17 and later 875 0058 05 RevC...
Страница 23: ...Setting Up the Reader M6 and Astra EX User Guide 23 Figure 7 M6 and Astra EX Status Page...
Страница 28: ...Networking the Reader M6 and Astra EX User Guide 28 Figure 8 M6 and Astra EX Settings Page...
Страница 34: ...Networking the Reader M6 and Astra EX User Guide 34 Figure 11 Fallback Interface Flowchard...
Страница 38: ...Networking the Reader M6 and Astra EX User Guide 38 Figure 12 M6 and Astra EX Reader Listing Page...
Страница 81: ...Compliance and IP Notices M6 and Astra EX User Guide 81 EU RED Declaration of Conformity...
Страница 83: ...Compliance and IP Notices M6 and Astra EX User Guide 83...
Страница 88: ...Appendix B M6 and Astra EX Dimensions M6 and Astra EX User Guide 88 Figure 22 Astra EX Dimensions...