“SI2”<AAAAAAA> Transparent
Gateway / Bridge command to Sensor-Interface SIF
(9.1756.x0.
1
00)
The command <AAAAAAA> (up to 7 signs) is send to COM2 or COM3
and the answer is given back. STX and ETX is added automatically.
Operation only if SIF configured.
Example: STX “SI2HH” ETX -> Help (HH) from Sensor-
Interface
“SO2”<AAAAAAAAA> Transparent
Gateway / Bridge command to SONIC. Works only for
commands with a single-line answer and if SONIC is configured.
The command <AAAAAAAAA> (up to 9 signs) is send to COM2 or
COM3 and the answer is given back. CR is added automatically.
Example: STX”SO200TT00000”ETX -> TT parameter is set 0
CR LF"?"CR LF
Response in case of unknown command or erroneous parameter
Table 9: List of commands
(*):
The internal divider of the clock will be reset by each write into the register. That means the
internal 1/100 second-register is reset and therefore the change of the second is manipulated.
ADDITIONAL CHARACTERS AND THEIR MEANING:
STX (0x02 Hex)
Start of command
ETX (0x03 Hex)
End of command
EOT (0x04 Hex)
End of memory data output by the commands:
"SS", "GS", “EE”, "ts", "ds", “TS”, “DS”, ”, "te", "de", “TE”, “DE”
XON (0x11 Hex)
Software-Handshake (continue output)
XOFF (0x13 Hex)
Software-Handshake (stop output; max. 4 minutes,
otherwise the logger turns itself off!)
Содержание DLx-MET