![Thies CLIMA DLx-MET Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/thies-clima/dlx-met/dlx-met_instructions-for-use-manual_1106913022.webp)
7. SENSOR 4 relative Humidity:
Rel.Humidity :
NNN.N %
Display of the instantaneously measured rel. Humidity.
Measuring range:
0.2 ... 100 % r.H. °C
Resolution:
0.1 % r.H.
8. SENSOR 5 Precipitation:
* Precipitation:
NNN.N mm
0.X I:N
Line 2:
Display of the amount of precipitation which has fallen during the current day.
The sum of all precipitation since midnight, including the during the
maintenance mode.
Line 3:
Display and input of the resolution of the sensor (0.1 -> 0.1mm, 0.2 ->
0.2mm) and current flow test of sensor (I:0 -> off I:1 -> on).
Serial commands: “NS” and “NT" (ref. to chap.
Measuring range:
0 ... 999.9 mm
Resolution:
0.1 / 0.2 mm
9. SENSOR 6 Air pressure:
Line 2:
Display of the instantaneously measured air pressure
* Air pressure :
NNNN.N hPa
Min:NNN Max:NNNNM
Line 3:
Display and input option for the measuring range of the air pressure sensor
Serial commands: “LM” and “LN" (ref. to chap.
Measuring range:
(500-900)* ... (900-1100)* hPa
Resolution:
0.1
hPa
* Note: measuring range adjustable (see Line 3)