31 - 66
021341/07/11
Command ZS
<id>ZS<para5>
Setting the sensor clock (second)
Description:
Setting the second. The sensor time can be requested by the command „ZT“
Value range:
0...59
Initial value:
0
Command ZD
<id>ZD<para5>
Setting the sensor date (day)
Description:
Setting the day. The sensor date can be requested by the command „ZT“.
Value range:
1...31
Initial value:
1
Command ZN
<id>ZN<para5>
Setting the sensor date (month)
Description:
Setting the month. The sensor date can be requested by the command „ZT“
Value range:
1...12
Initial value:
1
Command ZY
<id>ZY<para5>
Setting the sensor date (year)
Description:
Setting the year. The sensor date can be requested by the command „ZT“
Value range:
0...99
Initial value:
5
Command ZT
<id>ZT
Request of sensor date and clock
Description:
Output of the sensor date and time.
Format: “TT.MM.JJ;HH:mm:SS” (example: “25.01.05;15:58:10”)
On resetting or activating the instrument the time is initialized with 00:00:00.
Value range:
--
Initial value:
(“01.01.05;00:00:00” set when power up without using UPS-input)