37 - 66
021341/07/11
Command AZ
<id>AZ
Alignment of sensor clock
Description:
Correction of clock accuracy. For standard requirements (accuracy approx. 10-
20 minutes/year) no correction is necessary. In case of higher requirements
the accuracy can be increased by this command.
As the clock accuracy depends on aging and temperature we recommend a
correction after one year of operation.
Resolution of correction: 1 millisecond/minute = 1,44 seconds/day
Parameter > 100 are negative
Example: AT00105 -> -5ms/min (-7.2s/day) correction of clock
Value range:
0…123
Initial value:
105
7.2.7 Quantity measurement commands
Command RA
<id>RA00001
Reset of precipitation quantity and duration of quantity measurement.
Description:
By this command the precipitation quantity, output in the telegram (parameter
no. 17 in telegram 4 to 10, see CH.
7.3.1
), is set to 0
Value range:
1
Initial value:
-
Command PT
<id>PT
Output of duration of quantity measurement.
Description:
The duration of the quantity measurement is output in the format „H:M“
(H=hour, M=minute, max. 9999 hours). The duration is set to 0 by the
command „RA“.
Note: no fixed number of signs
Value range:
-
Initial value:
-
Содержание 5.4110 00 Series
Страница 65: ...65 66 021341 07 11...