54 - 66
021341/07/11
7.3.4 Telegram 10: Synop, Metar, optional measurement channels,
averaging
This telegram is transmtted by the instrument automatically in case the parameter “TM (chap.
7.2.3
.)
is set to 10. The time interval for automatic transmission and the averaging period is set through
command “TO” (chap.
7.2.3
.)
The query of the telegram is carried out in the polling mode through command “<id>TR00010”.
Separator
:
(semicolon)
Decimal separator
: (point)
Telegram start
STX(02)
Telegram end:
CR(13), LF(10), ETX(03) (carriage return, line feed, ETX)
Fix lengths and leading zeros
Error recognition:: biggest presentable number is output, in case no data are available (for ex. 99.9)
:
Example telegram 10:
00;0999;2.40;02.01.07;10:40:00;00;00;NP
;000.000;00;00;NP;000.000;000.000;000.000;0000.00;99999;-
9.9;100;0.0;0;0;0;0;0;0;0;0;0;0;0;0;0;0;0;0;+19;28;1626;4010;2384;235;090;070;99999;999;9999;99
99;9999;00000;99999;99999;9999;999;04;002.675;005.900;61;00;00;75;61;62;51;61;61;61;51;F4;