© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany
021814/03/21
Phone +49 551 79001-0 · Fax +49 551 79001-65 · [email protected] · www.thiesclima.com
Page 69 of 86
12 Appendix 1 Data Telegrams
12.1 Telegram 1
The wind transmitter responds with the measured value telegram to the command “00TR1\r”.
The table below shows the telegram structure:
Position
Length Example
Description
1
1
STX
Start character (start of text)
2
2
xx
Identification number (ID)
xx: 0…99
4
1
;
Separation character (’;’)
5
4
xx.x
Instantaneous value of the wind velocity, calculated with the
current calibration table; unit: m/s; resolution: 0.1m/s;
MODBUS-Register: 30001. When there is no calibration table
existing the calculated measuring value of the standard char-
acteristic curve is output.
9
1
;
Separation character (’;’)
10
4
xx.x
Instantaneous value of the wind velocity, calculated with the
standard curve; unit: m/s; resolution: 0.1m/s
MODBUS-Register: 30005.
14
1
;
Separation character (’;’)
15
6
xxxx.x
Measured frequency; unit: Hz; resolution 0.1Hz
MODBUS-Register: 35049.
21
1
;
Separation character (’;’)
22
4
xx.x
Current gust of the wind velocity of the last 1min., calculated
with the current calibration table; unit: m/s; resolution: 0.1m/s;
MODBUS-Register: 30011.
26
1
;
Separation character (’;’)
27
4
xx.x
Current minimum value of the wind velocity of the last 1min.,
calculated with the current calibration table; unit: m/s; resolu-
tion: 0.1m/s; MODBUS-Register: 30009.
31
1
;
Separation character (’;’)
32
4
xx.x
Current average value of the wind velocity, calculated accord-
ing command MS; unit: m/s; resolution: 0.1m/s; period: Averag-
ing interval (
Command MI) ; MODBUS-Register: 30003.
36
1
;
Separation character (’;’)
37
4
xx.x
Current standard deviation of the wind velocity, calculated with
the current calibration table; unit: m/s; resolution: 0.1m/s; pe-
riod: Averaging (
Command MI); MODBUS-Register: 30007.
41
1
;
Separation character (’;’)
42
5
xx.xx
Current degree of turbulence of wind speed, calculated accord-
ing to command MS; unit: without dimension; resolution: 0.01;
MODBUS-Register: 35057.
47
1
;
Separation character (’;’)
48
5
yxx.x
Housing interior temperature of the wind transmitter
(unit: °C); MODBUS-Register: 30403
y: Sign (+ or -)
xx.x: Temperature value; resolution: 0.1°C