11 Interface
The interface to the wind transmitter consists of an RS485 connection (half duplex mode)
with the following data format:
•
9600 baud (the baud rate can be set with the
•
8 data bits.
•
No parity.
•
1 stop bit.
•
Data in ASCII format (command interpreter: THIES).
•
Data in binary format (command interpreter: MODBUS RTU).
The behavior (configuration) of the wind transmitter can be changed with the commands
available (see
). For the command interpreter of the type
THIES, the query of the measured values is done with the
For the start of the wind transmitter, the character string “WG, software version and serial
number” is output.
Example:
WG THIES ADV X
v01.09
0007140006
Note:
The start message is output at the set baud rate (see "Command BR") and the data format
8N1 (8 data bits, no parity, 1 stopbit)!