Operation/installation/service manual
MACERATOR TOILETS
Manuale di utilizzo / installazione / manutenzione
TOILET MACERATRICI
X-light / Privilege/ Evolution/ Breeze/ E-Breeze/ Silence Plus 2G/ Elegance 2G
56
TECMA SRL – Via Flaminia / Loc Castel delle Formiche/ 05030 Otricoli (TR) / Italy-
rev 1.2017
1111111111111111
111111111111111111111
3.3 Solenoid valve
Before installing the solenoid valve, clean the pipes (brazing or welding residues, metal chips, seal
material). A filter inside the solenoid valve prevents failures resulting from water impurities. We
recommend cleaning the solenoid valve filter regularly. After service, screw both fitting back with
the respective gaskets to the solenoid valve and tighten with a torque of 2 N/m. Do not force the
solenoid valve when tightening it. Do not obstruct the pilot hole at the valve outlet. The entire
piping section must be free from bottlenecks. Comply with the recommended pressure range
(refer to section 7.0).
The solenoid can be regularly installed on the fresh water supply line, or - alternatively - integrated
in the WC through an optional hose connection that connects directly the water inlet tube as
shown in the following sequence.
*
Installation of optional adapter
for installation integrated solenoid
in the bowl.