THERMOSALD UPSCR_N_V5 - OPERATOR MANUAL - Rev. 2006 / 07
Page N. 7
- Tot: 18
4 – START UP
4.1 – START UP – START UP WITH GENERAL RESET
1 - The machine must be at ambient temperature.
2 - Pre-heat and seal remote controls must be off.
3 - Set dip switch SW+/SW- according to the rated voltage of the power trasformer; see next CALCULATION
TABLE and DIP SWITCH SW+ / SW- TABLE:
CALCULATION TABLE
Example:
Sealing band = 1
Ω
- RATED I = 30 A,
TRASFORMER RATED VOLTAGE = 30 V
TRASFORMER MAXIMUM VOLTAGE = 30 V x 1.5 = 45 V
TRASFORMER SECONDARY VOLTAGE = Compresa fra 30V e 45V
DIP SWITCH SW+ e SW- = OFF OFF ON ON (See DIP SWITCH SW+ / SW- TABLE)
NOTE: SW+ e SW- set depend on
TRASFORMER RATED VOLTAGE = 30V (field 26V - 35 V )
(don’t depend on TRASFORMER SECONDARY VOLTAGE)
DIP SWITCH SW+ / SW- TABLE
Dip 1
Dip 2
Dip3
Dip4 TRASFORMER RATED VOLTAGE
ON
ON
ON
ON
05 - 07
(TO LIGHT GREEN LED)
OFF
ON
ON
ON
08 - 15
ON
OFF
ON
ON
16 - 25
OFF
OFF
ON
ON
26 - 35
ON
ON
OFF
ON
36 - 42
OFF
ON
OFF
ON
43 - 50
ON
OFF
OFF
ON
51 - 57 binary system
OFF
OFF
OFF
ON
58 - 65
ON
ON
ON
OFF
66 - 75
OFF
ON
ON
OFF
76 - 82
ON
OFF
ON
OFF
83 - 92
OFF
OFF
ON
OFF
93 - 97
ON
ON
OFF
OFF
97 - 100
OFF
ON
OFF
OFF
-
ON
OFF
OFF
OFF
-
OFF
OFF
OFF
OFF
-
( TO LIGHT RED LED)